Complications · Patients with insufficient bone below the maxillary sinus requiring dental implants
1 finding from 1 review
Raghoebar 2005: 1 complication in the non-PRP arm, OR 0.27 (0.01 to 8.46), P = 0.46; Torres 2009 (PRP only = 3, no-PRP only = 2), OR 1.49 (0.15 to 15.07), P = 1.00. No statistically significant difference.
2 studies · 62 participants
GRADE not reported
Alteration of hyperdivergent growth pattern · Children and adolescents (over 80% aged 16 years or younger at treatment start) with anterior open bite (lack of vertical overlap or…
1 finding from 1 review
The angles (SN.GoGN, SN.PP, NS.Gn) and linear measures (AFA, AFP, AFAI) did not demonstrate significant alterations between groups; interventions did not produce significant changes in the skeletal maxillary or…
1 study
GRADE not reported
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
SPI Element sand-blasted acid-etched standard implants showed no clear difference in marginal bone level change compared with SPI Element SurfLink-modified implants; GRADE not reported.
1 finding from 1 review
Complications (at treated sites) · Patients with missing teeth and an atrophic posterior maxilla, with residual bone height between 4 and 9 mm below the maxillary sinus
Maxillary sinus lift (augmentation) with long implants may leads to higher complications (at treated sites) compared with short implants (5 to 8.5 mm) without sinus augmentation (low certainty).
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
ITI SLA titanium screws showed no clear difference in marginal bone level change compared with southern blasted/etched titanium screws; GRADE not reported.
1 finding from 1 review
Pancreatic cancer · Adults (general population)
Meta-analysis of observational studies (higher vs lower 25(OH)D) for Pancreatic cancer: OR 2.13 (95% CI 1.02 to 4.47), statistically significant. Umbrella review outcome-level evidence grade: No conclusion.
1 finding from 1 review
Hip Fracture · Adults (general population)
Meta-analysis of observational studies (higher vs lower 25(OH)D) for Hip fracture (Population-based controls): log ratio of geometric mean -0.51 (95% CI -0.64 to -0.38), statistically significant. Umbrella review outcome-level evidence grade: No conclusion.
2 findings from 1 review
log ratio of geometric mean -0.51 [-0.64, -0.38]
9 studies · 1655 participants
GRADE not reported
log ratio of geometric mean -0.26 [-0.33, -0.23]
8 studies · 2201 participants
GRADE not reported
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelActive external connection implants showed no clear difference in implant failure compared with nobelReplace implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark IV TiUnite titanium screws showed no clear difference in implant failure compared with southern regular titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Augmentation procedure failure · Patients with missing teeth and an atrophic posterior maxilla, with residual bone height between 4 and 9 mm below the maxillary sinus
1 finding from 1 review
Non-Hodgkin's lymphoma · Adults (general population)
Meta-analysis of observational studies (higher vs lower 25(OH)D) for Non-Hodgkin's lymphoma (Females): OR 0.81 (95% CI 0.39 to 1.70), not statistically significant. Umbrella review outcome-level evidence grade: No conclusion.
2 findings from 1 review
Hypertension · Adults (general population)
Meta-analysis of observational studies (higher vs lower 25(OH)D) for Hypertension: RR 0.70 (95% CI 0.58 to 0.86), statistically significant. Umbrella review outcome-level evidence grade: Suggestive.
1 finding from 1 review
Patient satisfaction · Children and adolescents (over 80% aged 16 years or younger at treatment start) with anterior open bite (lack of vertical overlap or…
The review found no eligible studies for this question.
1 finding from 1 review
Aggressive prostate cancer · Adults (general population)
Meta-analysis of observational studies (higher vs lower 25(OH)D) for Aggressive prostate cancer: OR 0.98 (95% CI 0.84 to 1.15), not statistically significant. Umbrella review outcome-level evidence grade: Substantial effect unlikely.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Astra TiO2-blasted titanium screws showed no clear difference in marginal bone level change compared with branemark turned titanium screws; GRADE not reported.
1 finding from 1 review
Cardiovascular mortality · Adults (general population)
Meta-analysis of observational studies (higher vs lower 25(OH)D) for Cardiovascular disease mortality: RR 0.55 (95% CI 0.36 to 0.85), statistically significant. Umbrella review outcome-level evidence grade: No conclusion.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
MegaGen EZ Plus blasted standard implants showed no clear difference in marginal bone level change compared with megaGen EZ Plus calcium-incorporated (Xpeed) implants; GRADE not reported.
1 finding from 1 review
Implant failure · Patients with missing teeth and an atrophic posterior maxilla, with residual bone height between 4 and 9 mm below the maxillary sinus
Maxillary sinus lift (augmentation) with long implants showed no clear difference in implant failure compared with short implants (5 to 8.5 mm) without sinus augmentation (moderate certainty).
1 finding from 1 review
Birth length · pregnant women and their infants..
Meta-analysis of observational studies (higher vs lower maternal 25(OH)D) for Birth length: WMD 0.19 (95% CI -0.26 to 0.65), not statistically significant. Umbrella review outcome-level evidence grade: Substantial effect unlikely.
1 finding from 1 review