Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
ITI SLA standard (regular neck) implants showed no clear difference in implant failure compared with ITI SLActive implants; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Ankylos Plus (Dentsply) implants showed no clear difference in marginal bone level change compared with seven (Sweden & Martina) implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Southern regular implants showed no clear difference in implant failure compared with southern wide implants; GRADE not reported.
1 finding from 1 review
Early implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Turned (smoother) implant surfaces showed no clear difference in early implant failure compared with roughened implant surfaces (low certainty).
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Astra TiO2-blasted titanium screws showed no clear difference in implant failure compared with branemark turned titanium screws; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
SPI Element sand-blasted acid-etched standard implants showed no clear difference in marginal bone level change compared with SPI Element SurfLink-modified implants; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
ITI SLA titanium screws showed no clear difference in marginal bone level change compared with southern blasted/etched titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelActive external connection implants showed no clear difference in implant failure compared with nobelReplace implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark IV TiUnite titanium screws showed no clear difference in implant failure compared with southern regular titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Astra TiO2-blasted titanium screws showed no clear difference in marginal bone level change compared with branemark turned titanium screws; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
MegaGen EZ Plus blasted standard implants showed no clear difference in marginal bone level change compared with megaGen EZ Plus calcium-incorporated (Xpeed) implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark IV turned titanium implants showed no clear difference in implant failure compared with branemark Mark IV TiUnite oxidised implants; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark IV turned titanium implants showed no clear difference in marginal bone level change compared with branemark Mark IV TiUnite oxidised implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
ITI SLActive titanium grade 4 implants showed no clear difference in implant failure compared with ITI SLActive titanium-13zirconium (Roxolid) implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelActive internal connection implants showed no clear difference in marginal bone level change compared with nobelReplace implants; GRADE not reported.
1 finding from 1 review
Peri-implantitis · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Turned (smoother) implant surfaces may leads to lower peri-implantitis compared with roughened implant surfaces (low certainty).
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelReplace Select Tapered implants showed no clear difference in marginal bone level change compared with nobelReplace Groovy implants; GRADE not reported.
1 finding from 1 review