Death or bronchopulmonary dysplasia at 36 weeks PMA · Neonates with developing BPD
Inhaled steroids showed no clear difference in death or BPD at 36 weeks' postmenstrual age compared with systemic steroids (moderate certainty).
2 findings from 1 review
Diastolic blood pressure > 95th percentile at 7 years · Neonates with developing BPD
Inhaled steroids probably leads to lower diastolic blood pressure > 95th percentile at 7 years compared with systemic steroids (moderate certainty).
1 finding from 1 review
Ever diagnosed as asthmatic by 7 years · Neonates with developing BPD
Inhaled steroids showed no clear difference in ever diagnosed as asthmatic by 7 years compared with systemic steroids (moderate certainty).
1 finding from 1 review
Bronchopulmonary dysplasia/chronic lung disease · Neonates with developing BPD
Inhaled steroids showed no clear difference in BPD at 36 weeks' postmenstrual age compared with systemic steroids (low certainty).
1 finding from 1 review
Hyperglycaemia · Neonates with developing BPD
Inhaled steroids showed no clear difference in hyperglycaemia compared with systemic steroids (low certainty).
1 finding from 1 review
Hypertension · Neonates with developing BPD
Inhaled steroids may leads to lower hypertension compared with systemic steroids (low certainty).
1 finding from 1 review
General conceptual ability (GCA) score at 7 years The test has a standardisation mean of 100 and SD of 15 · Neonates with developing BPD
Inhaled steroids showed no clear difference in general conceptual ability (GCA) score at 7 years The test has a… compared with systemic steroids (moderate certainty).
1 finding from 1 review
Moderate/severe disability at 7 years · Neonates with developing BPD
Inhaled steroids showed no clear difference in moderate/severe disability at 7 years compared with systemic steroids (moderate certainty).
1 finding from 1 review
Death or moderate/severe disability at 7 years · Neonates with developing BPD
Inhaled steroids showed no clear difference in death or moderate/severe disability at 7 years compared with systemic steroids (moderate certainty).
1 finding from 1 review
Systolic blood pressure > 95th percentile at 7 years · Neonates with developing BPD
Inhaled steroids showed no clear difference in systolic blood pressure > 95th percentile at 7 years compared with systemic steroids (moderate certainty).
1 finding from 1 review
Prelabour rupture of membranes · women with a twin pregnancy
Oral betamimetic showed no clear difference in prelabour rupture of membranes compared with placebo (low certainty).
1 finding from 1 review