Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

106 questions · 127 findings · 11 reviews · Oral Health

No studies found 1 · 0.8%GRADE not reported 59 · 46.5%Very low 6 · 4.7%Low 20 · 15.7%Moderate 41 · 32.3%High 0 · 0%

Mesoporous silica (SiO2) vs Calcium-based agent

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Silica vs Calcium showed no significant difference in 24 h bond strength (MD 1.964, 95% CI -5.802 to 9.730; Moderate certainty).

1 finding from 1 review

Self-assembling/remineralizing peptide (e.g., P11-4, PAA-PASP) vs Fluoride agent (e.g., NaF/SDF/KF/CaF2)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Fluorine showed no significant difference in 24 h bond strength (MD 2.131, 95% CI -2.213 to 6.475; Low certainty).

3 findings from 1 review

Calcium phosphate agent (e.g., CPP-ACP, Ca/P-PILP, niobophosphate) vs Calcium-based agent

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + chemical ACAD protocol network, Calcium Phosphate vs Calcium showed no significant difference in 24 h bond strength (MD 0.596, 95% CI -7.289 to 8.482; Low certainty).

2 findings from 1 review

Silver diamine fluoride (SDF) vs No biomimetic remineralization (control)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

Only one in vitro study assessed a Self-Etch adhesive with the biological ACAD protocol; it was insufficient for network meta-analysis, so no pooled effect estimate is available (ungraded).

1 finding from 1 review

Self-assembling/remineralizing peptide (e.g., P11-4, PAA-PASP) vs No biomimetic remineralization (control)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Control showed no significant difference in 24 h bond strength (MD 1.530, 95% CI -2.373 to 5.434; Moderate certainty).

3 findings from 1 review

Calcium-based agent vs Fluoride agent (e.g., NaF/SDF/KF/CaF2)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Calcium vs Fluorine showed no significant difference in 24 h bond strength (MD -0.523, 95% CI -5.404 to 4.358; Low certainty).

1 finding from 1 review

Fluoride agent (e.g., NaF/SDF/KF/CaF2) vs No biomimetic remineralization (control)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + biological ACAD protocol network, Fluorine showed 4.197 MPa higher 24 h bond strength than Control (MD 4.197, 95% CI 1.080 to 7.314; Moderate certainty).

3 findings from 1 review

Self-assembling/remineralizing peptide (e.g., P11-4, PAA-PASP) vs Hydroxyapatite (e.g., nano-HAp)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + chemical ACAD protocol network, Peptide vs HAp showed no significant difference in 24 h bond strength (MD -0.288, 95% CI -7.988 to 7.411; Very Low certainty).

2 findings from 1 review

Hydroxyapatite (e.g., nano-HAp) vs HEMA/EGDMA-based desensitizer

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, HAp vs HEMA showed no significant difference in 24 h bond strength (MD -4.815, 95% CI -10.709 to 1.079; Moderate certainty).

1 finding from 1 review

Flavonoids (e.g., quercetin, proanthocyanidin) vs Calcium phosphate agent (e.g., CPP-ACP, Ca/P-PILP, niobophosphate)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + biological ACAD protocol network, Flavonoids showed 12.771 MPa lower 24 h bond strength than Calcium Phosphate (MD -12.771, 95% CI -20.538 to -5.003; Moderate certainty).

2 findings from 1 review

Calcium phosphate vs control

Immediate (24 h) resin-dentin bond strength (MPa) · permanent human teeth with artificial caries-affected dentin

Calcium phosphate minus Control was -21.209 MPa (95% CI -25.954 to -16.463) at 24 h.

2 findings from 1 review

Flavonoids (e.g., quercetin, proanthocyanidin) vs No biomimetic remineralization (control)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + biological ACAD protocol network, Flavonoids showed 8.438 MPa higher 24 h bond strength than Control (MD 8.438, 95% CI 2.289 to 14.587; Moderate certainty).

2 findings from 1 review

HEMA/EGDMA-based desensitizer vs Calcium-based agent

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, HEMA vs Calcium showed no significant difference in 24 h bond strength (MD 3.023, 95% CI -3.815 to 9.861; Moderate certainty).

1 finding from 1 review

Self-assembling/remineralizing peptide (e.g., P11-4, PAA-PASP) vs HEMA/EGDMA-based desensitizer

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs HEMA showed no significant difference in 24 h bond strength (MD -0.369, 95% CI -6.728 to 5.990; Low certainty).

1 finding from 1 review

Hydroxyapatite (e.g., nano-HAp) vs No biomimetic remineralization (control)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, HAp vs Control showed no significant difference in 24 h bond strength (MD -2.916, 95% CI -5.854 to 0.023; Moderate certainty).

2 findings from 1 review

HEMA/EGDMA-based desensitizer vs Calcium phosphate agent (e.g., CPP-ACP, Ca/P-PILP, niobophosphate)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, HEMA vs Calcium Phosphate showed no significant difference in 24 h bond strength (MD 0.360, 95% CI -5.589 to 6.309; Moderate certainty).

1 finding from 1 review

Hydroxyapatite (e.g., nano-HAp) vs Fluoride agent (e.g., NaF/SDF/KF/CaF2)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + chemical ACAD protocol network, HAp vs Fluorine showed no significant difference in 24 h bond strength (MD 4.960, 95% CI -1.806 to 11.727; Low certainty).

2 findings from 1 review

Flavonoids (e.g., quercetin, proanthocyanidin) vs HEMA/EGDMA-based desensitizer

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Flavonoids vs HEMA showed no significant difference in 24 h bond strength (MD 2.705, 95% CI -5.654 to 11.063; Moderate certainty).

1 finding from 1 review