Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Southern regular implants showed no clear difference in implant failure compared with southern wide implants; GRADE not reported.
1 finding from 1 review
Early implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Turned (smoother) implant surfaces showed no clear difference in early implant failure compared with roughened implant surfaces (low certainty).
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Astra TiO2-blasted titanium screws showed no clear difference in implant failure compared with branemark turned titanium screws; GRADE not reported.
1 finding from 1 review
Complications · Patients with insufficient bone below the maxillary sinus requiring dental implants
1 finding from 1 review
Raghoebar 2005: 1 complication in the non-PRP arm, OR 0.27 (0.01 to 8.46), P = 0.46; Torres 2009 (PRP only = 3, no-PRP only = 2), OR 1.49 (0.15 to 15.07), P = 1.00. No statistically significant difference.
2 studies · 62 participants
GRADE not reported
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
SPI Element sand-blasted acid-etched standard implants showed no clear difference in marginal bone level change compared with SPI Element SurfLink-modified implants; GRADE not reported.
1 finding from 1 review
Complications (at treated sites) · Patients with missing teeth and an atrophic posterior maxilla, with residual bone height between 4 and 9 mm below the maxillary sinus
Maxillary sinus lift (augmentation) with long implants may leads to higher complications (at treated sites) compared with short implants (5 to 8.5 mm) without sinus augmentation (low certainty).
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
ITI SLA titanium screws showed no clear difference in marginal bone level change compared with southern blasted/etched titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelActive external connection implants showed no clear difference in implant failure compared with nobelReplace implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark IV TiUnite titanium screws showed no clear difference in implant failure compared with southern regular titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Augmentation procedure failure · Patients with missing teeth and an atrophic posterior maxilla, with residual bone height between 4 and 9 mm below the maxillary sinus
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Astra TiO2-blasted titanium screws showed no clear difference in marginal bone level change compared with branemark turned titanium screws; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
MegaGen EZ Plus blasted standard implants showed no clear difference in marginal bone level change compared with megaGen EZ Plus calcium-incorporated (Xpeed) implants; GRADE not reported.
1 finding from 1 review
Implant failure · Patients with missing teeth and an atrophic posterior maxilla, with residual bone height between 4 and 9 mm below the maxillary sinus
Maxillary sinus lift (augmentation) with long implants showed no clear difference in implant failure compared with short implants (5 to 8.5 mm) without sinus augmentation (moderate certainty).
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark IV turned titanium implants showed no clear difference in implant failure compared with branemark Mark IV TiUnite oxidised implants; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark IV turned titanium implants showed no clear difference in marginal bone level change compared with branemark Mark IV TiUnite oxidised implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
ITI SLActive titanium grade 4 implants showed no clear difference in implant failure compared with ITI SLActive titanium-13zirconium (Roxolid) implants; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelActive internal connection implants showed no clear difference in marginal bone level change compared with nobelReplace implants; GRADE not reported.
1 finding from 1 review
Peri-implantitis · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Turned (smoother) implant surfaces may leads to lower peri-implantitis compared with roughened implant surfaces (low certainty).
1 finding from 1 review