Aesthetics assessed by dentist: position of the perimplant tissues · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate-delayed implants (placed within 8 weeks after tooth… led to higher aesthetics assessed by dentist: position of the perimplant tissues compared with delayed implants (placed at least 2 months after extraction); GRADE not reported.
1 finding from 1 review
Marginal bone level change · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate-delayed implants (placed within 8 weeks after tooth… showed no clear difference in perimplant marginal bone level changes compared with delayed implants (placed at least 2 months after extraction); GRADE not reported.
1 finding from 1 review
Patients' aesthetic perception (satisfaction with crown appearance) · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate-delayed implants (placed within 8 weeks after tooth… showed no clear difference in patients' aesthetic perception (satisfaction with crown appearance) compared with delayed implants (placed at least 2 months after extraction); GRADE not reported.
1 finding from 1 review
Prosthesis failure · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate-delayed implants (placed within 8 weeks after tooth… led to lower prosthesis failure compared with delayed implants (placed at least 2 months after extraction); GRADE not reported.
1 finding from 1 review
Satisfaction with treatment ‐ general · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate-delayed implants (placed within 8 weeks after tooth… led to higher patients' general satisfaction of treatment compared with delayed implants (placed at least 2 months after extraction); GRADE not reported.
1 finding from 1 review
Patients' perception of how long treatment took · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate-delayed implants (placed within 8 weeks after tooth… led to lower patients' perception of how long treatment took compared with delayed implants (placed at least 2 months after extraction); GRADE not reported.
1 finding from 1 review
Marginal bone level change · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate implants (placed in a fresh extraction socket just after… showed no clear difference in perimplant marginal bone level changes compared with delayed implants (placed at least 2 months after extraction, in…; GRADE not reported.
1 finding from 1 review
Prosthesis failure · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate implants (placed in a fresh extraction socket just after… showed no clear difference in prosthesis failure compared with delayed implants (placed at least 2 months after extraction, in…; GRADE not reported.
1 finding from 1 review
Aesthetics assessed by dentist: position of the perimplant tissues · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate implants (placed in a fresh extraction socket just after… led to lower aesthetics assessed by dentist: position of the perimplant tissues compared with delayed implants (placed at least 2 months after extraction, in…; GRADE not reported.
1 finding from 1 review
One year after placement, there were no statistically significant differences for the level of the perimplant marginal mucosa in relation to that of the adjacent teeth (Lindeboom 2006).
1 study · 50 participants
GRADE not reported
Implant failure · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate implants (placed in a fresh extraction socket just after… showed no clear difference in implant failure compared with delayed implants (placed at least 2 months after extraction, in…; GRADE not reported.
1 finding from 1 review
Overall success (composite of clinical and radiographic success) · Adults aged 18 years or older with mature permanent teeth and carious pulp exposure
Immediate permanent restoration was associated with a pooled success rate of 89.9%.
1 finding from 1 review
Overall success (composite of clinical and radiographic success) · Adults (>=18 y) with mature permanent teeth and deep carious pulp exposure
Immediate permanent restoration after partial pulpotomy is associated with much higher success than delayed restoration (89.9% immediate vs 23.2% beyond 14 days; ungraded).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Silica vs Fluorine showed no significant difference in 24 h bond strength (MD 1.441, 95% CI -5.099 to 7.980; Moderate certainty).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, HAp vs Calcium showed no significant difference in 24 h bond strength (MD -1.792, 95% CI -7.415 to 3.831; Low certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Etch-and-Rinse adhesive + biological ACAD protocol network, Flavonoids vs Fluorine showed no significant difference in 24 h bond strength (MD 4.241, 95% CI -2.652 to 11.135; Moderate certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · permanent human teeth with artificial caries-affected dentin
Calcium minus Control was -0.508 MPa (95% CI -8.207 to 7.191) at 24 h.
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Calcium Phosphate showed no significant difference in 24 h bond strength (MD -0.009, 95% CI -4.076 to 4.058; Low certainty).
3 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, HEMA vs Control showed no significant difference in 24 h bond strength (MD 1.899, 95% CI -3.210 to 7.009; Low certainty).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Calcium Phosphate vs Fluorine showed no significant difference in 24 h bond strength (MD 2.140, 95% CI -1.506 to 5.787; Moderate certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Calcium showed no significant difference in 24 h bond strength (MD 2.654, 95% CI -3.216 to 8.524; Moderate certainty).
2 findings from 1 review