Change in gingival recession (REC) · People with at least one dental implant affected by perimplantitis
Er:YAG laser debridement showed no clear difference in change in gingival recession (REC) compared with manual debridement plus chlorhexidine irrigation/gel; GRADE not reported.
1 finding from 1 review
Change in probing attachment level (PAL) · People with at least one dental implant affected by perimplantitis
Er:YAG laser debridement showed no clear difference in change in probing attachment level (PAL) compared with manual debridement plus chlorhexidine irrigation/gel; GRADE not reported.
1 finding from 1 review
Change in probing pocket depth (PPD) · People with at least one dental implant affected by perimplantitis
Nanocrystalline hydroxyapatite (Ostim) led to lower change in probing pocket depth (PPD) compared with bovine-derived xenograft (Bio-Oss) plus resorbable barrier; GRADE not reported.
1 finding from 1 review
Patient satisfaction · Partially edentulous patients treated with a distal-extension RDP
1 finding from 1 review
Complications and side effects · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Change in probing pocket depth (PPD) · People with at least one dental implant affected by perimplantitis
Metronidazole gel 25% (local antibiotic) showed no clear difference in change in probing pocket depth compared with ultrasonic debridement; GRADE not reported.
1 finding from 1 review
Implant failure · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Recurrence of peri-implantitis · People with at least one dental implant affected by perimplantitis
Er:YAG laser led to lower recurrence of peri-implantitis compared with air-abrasive device (Perio-Flow); GRADE not reported.
1 finding from 1 review
After 6 months no statistically significant difference for peri-implantitis recurrence; 11% of implants (five air-abrasive, six laser) had pus on probing.
1 study · 42 participants
GRADE not reported
Change in probing attachment level (PAL) · People with at least one dental implant affected by perimplantitis
Adjunctive local antibiotic (8.5% doxycycline hyclate, Atridox)… led to higher change in probing attachment level (PAL) compared with manual debridement with chlorhexidine (no antibiotic); GRADE not reported.
1 finding from 1 review
Recurrence of peri-implantitis · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Change in probing pocket depth (PPD) · People with at least one dental implant affected by perimplantitis
Er:YAG laser showed no clear difference in change in probing pocket depth compared with air-abrasive device (Perio-Flow); GRADE not reported.
1 finding from 1 review
Implant failure · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Recurrence of peri-implantitis · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Complications and side effects · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
No implant failures, complications or recurrence of peri-implantitis occurred in any of the groups.
1 study · 27 participants
GRADE not reported
Implant failure · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Change in probing attachment level (PAL) · People with at least one dental implant affected by perimplantitis
Nanocrystalline hydroxyapatite (Ostim) led to lower change in probing attachment level (PAL) compared with bovine-derived xenograft (Bio-Oss) plus resorbable barrier; GRADE not reported.
1 finding from 1 review
Complications and side effects · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Implant failure · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Complications and side effects · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Implant failure · People with at least one dental implant affected by perimplantitis
1 finding from 1 review