Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

558 questions · 704 findings · 64 reviews · Dental caries

No studies found 91 · 12.9%GRADE not reported 441 · 62.6%Very low 76 · 10.8%Low 73 · 10.4%Moderate 21 · 3%High 2 · 0.3%

Fluoride-releasing resin-based sealant vs Resin-based sealant

Development of >=1 new carious lesion (caries incidence) · Children with caries-free second primary molars, aged 4-8 years (dental clinic, Turkey and Spain)
1 finding from 1 review
  • Sealants for preventing dental caries in primary teeth 2022 · Cochrane All outcomes
    6-24 months
    N/A - insufficient quantitative information available; 69 (2 studies). Comments: Due to the different sealant materials, data reporting (split-mouth studies reported as parallel-group) and the very low number of tooth…
    2 studies · 69 participants
    Low

Glass ionomer-based sealant vs No sealant (control/no treatment)

Dental caries increment, DMFT/dmft (whole-tooth level) · Children with caries-free primary first molars (with or without caries on other teeth), aged 1-5 years (paediatric clinic/dental school,…
1 finding from 1 review
  • Sealants for preventing dental caries in primary teeth 2022 · Cochrane All outcomes
    12 months
    Joshi 2019: dmft 8.43 (SD 5.84) with sealant vs 10.05 (SD 6.16) with no sealant at 12 months (caries threshold uncertain); Chadwick 2005: no significant difference in caries increment on occlusal surfaces, no summary…
    2 studies
    GRADE not reported

Antiretroviral therapy (any, including cART) vs No antiretroviral medication (treatment-naive)

Caries experience · Children and adolescents (<18 years) living with HIV (CLWH)

ART was not associated with a significant difference in dental caries experience among CLWH (very low certainty).

1 finding from 1 review

Laser fluorescence (DIAGNOdent 2190/pen) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic accuracy (sensitivity and specificity) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
  • Fluorescence devices for the detection of dental caries 2020 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    Analysed as a separate index test (coupled forest plot and SROC plot, Figure 22 / Figure 23; Appendix 5); no summary DOR or sensitivity/specificity point reported numerically in the text. 34 datasets, 6842 tooth sites.
    32 studies
    GRADE not reported

Laser fluorescence (LF; DIAGNOdent) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic accuracy (sensitivity and specificity) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
  • Fluorescence devices for the detection of dental caries 2020 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    Analysed as a separate index test (coupled forest plot and SROC plot, Figure 22 / Figure 23; Appendix 5); no summary DOR or sensitivity/specificity point reported numerically in the text. 46 datasets, 7316 tooth sites.
    45 studies
    GRADE not reported

Red fluorescence devices (DIAGNOdent, DIAGNOdent pen, MidWest; excitation wavelength >655 nm) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) by subgroup: Medium dentine-caries prevalence (15% to 34%) (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) by subgroup: Histology or excavation reference standard (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) by subgroup: Permanent/mixed dentition (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) by subgroup: Low dentine-caries prevalence (<=14%) (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity at fixed upper-quartile specificity 0.90 (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) by subgroup: Single site per tooth (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) by subgroup: Radiography reference standard (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) by subgroup: Enhanced visual examination reference standard (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Blue fluorescence devices (VistaProof, SoproLife, Spectra; wavelength 400-450 nm) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic accuracy (sensitivity and specificity) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
  • Fluorescence devices for the detection of dental caries 2020 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    Analysed as a separate index test (coupled forest plot and SROC plot, Figure 24 / Figure 25; Appendix 5); no summary DOR or sensitivity/specificity point reported numerically in the text. 3 datasets, 1027 tooth sites.
    3 studies
    GRADE not reported