Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

21 questions · 41 findings · 4 reviews

No studies found 0 · 0%GRADE not reported 36 · 87.8%Very low 1 · 2.4%Low 4 · 9.8%Moderate 0 · 0%High 0 · 0%

Electrical conductance devices (electronic caries monitor (ECM) and/or CarieScan Pro), used as an adjunct to clinical oral examination vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
2 findings from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies) · Permanent dentition
    Permanent dentition (4 studies): sensitivity ranged from 0.55 to 0.65.
    4 studies
    GRADE not reported
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies) · Primary dentition
    Primary dentition (3 studies): sensitivity ranged from 0.91 to 0.93. No evidence of a difference in accuracy by dentition (removing accuracy covariate: Chi2=3.15, df=1, P=0.08).
    3 studies
    GRADE not reported

CarieScan Pro device vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    CarieScan Pro (3 studies, 244 tooth surfaces): sensitivity ranged from 0.55 to 0.91. No evidence of a difference in accuracy by device type (Chi2=0.05, df=1, P=0.82).
    3 studies
    GRADE not reported

Electronic caries monitor (ECM) device (ECM II / ECM III / ECM IV) vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    ECM (4 studies, 475 tooth surfaces): sensitivity ranged from 0.61 to 0.98 (0.61-0.65 in three studies; 0.98 in the most recent ECM IV study). No evidence of a difference in accuracy by device type (Chi2=0.05, df=1,…
    4 studies
    GRADE not reported

Near-infrared (NIR) transillumination vs Reference standard (histology, excavation, radiographs/microCT, or tooth separation)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Fibre-optic transillumination (FOTI) vs Reference standard (histology, excavation, radiographs/microCT, or tooth separation)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Optical coherence tomography (OCT) vs Reference standard (histology, excavation, radiographs/microCT, or tooth separation)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Transillumination and optical coherence tomography devices (all illumination devices combined: NIR, OCT, and FOTI/DIFOTI) vs Reference standard (histology, excavation, radiographs/microCT, or tooth separation)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Electrical conductance devices (electronic caries monitor (ECM) and/or CarieScan Pro), used as an adjunct to clinical oral examination vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity for detection of enamel caries · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    SoF findings (HSROC; no summary operating point reported): 'ECM: sensitivity from 0.61 to 0.98 ... CarieScan Pro: sensitivity from 0.55 to 0.91'. Across all 7 studies (8 datasets), covering 719 tooth surfaces or sites…
    7 studies
    Very low

Analogue (conventional) radiographs vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Radiographic imaging methods (any: analogue radiographs, digital radiographs, or CBCT) vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
17 findings from 1 review
Show 14 more findings

Cone beam computed tomography (CBCT) vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
3 findings from 1 review

Analogue (conventional) radiographs vs Digital radiographs (direct within-person / paired comparison); reference standard: histology, excavation, or enhanced visual examination

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
2 findings from 1 review

Digital radiographs vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity at fixed median specificity 0.78 (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

VistaProof (Durr Dental; blue fluorescence, 405 nm) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic accuracy (sensitivity and specificity) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
  • Fluorescence devices for the detection of dental caries 2020 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    Analysed as a separate index test (coupled forest plot and SROC plot, Figure 24 / Figure 25; Appendix 5); no summary DOR or sensitivity/specificity point reported numerically in the text. 18 datasets, 2402 tooth sites.
    17 studies
    GRADE not reported

Laser fluorescence (DIAGNOdent 2190/pen) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic accuracy (sensitivity and specificity) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
  • Fluorescence devices for the detection of dental caries 2020 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    Analysed as a separate index test (coupled forest plot and SROC plot, Figure 22 / Figure 23; Appendix 5); no summary DOR or sensitivity/specificity point reported numerically in the text. 34 datasets, 6842 tooth sites.
    32 studies
    GRADE not reported

Laser fluorescence (LF; DIAGNOdent) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic accuracy (sensitivity and specificity) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
  • Fluorescence devices for the detection of dental caries 2020 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    Analysed as a separate index test (coupled forest plot and SROC plot, Figure 22 / Figure 23; Appendix 5); no summary DOR or sensitivity/specificity point reported numerically in the text. 46 datasets, 7316 tooth sites.
    45 studies
    GRADE not reported

Spectra caries detection device (Air Techniques; blue fluorescence) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic accuracy (sensitivity and specificity) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
  • Fluorescence devices for the detection of dental caries 2020 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    The Spectra caries detection device fits into the blue fluorescence category but no studies provided data for inclusion in the meta-analysis (Markowitz 2015).
    1 study
    GRADE not reported

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity at fixed upper-quartile specificity 0.90 (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Blue fluorescence devices (VistaProof, SoproLife, Spectra; wavelength 400-450 nm) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic accuracy (sensitivity and specificity) for detection of early enamel caries (D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
  • Fluorescence devices for the detection of dental caries 2020 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    Analysed as a separate index test (coupled forest plot and SROC plot, Figure 24 / Figure 25; Appendix 5); no summary DOR or sensitivity/specificity point reported numerically in the text. 3 datasets, 1027 tooth sites.
    3 studies
    GRADE not reported