6 questions · 17 findings · 1 reviews · Esthetic dentistry

No studies found 0 · 0%GRADE not reported 14 · 82.4%Very low 2 · 11.8%Low 1 · 5.9%Moderate 0 · 0%High 0 · 0%

In-office laser therapy (all types combined) vs Placebo (placebo laser or placebo agent) or no treatment

Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation

It is very uncertain whether in-office laser therapy (all types combined) changes changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment (very low certainty).

3 findings from 1 review

Er,Cr:YSGG laser (erbium,chromium:yttrium-scandium-gallium-garnet) vs Placebo (placebo laser or placebo agent) or no treatment

Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation

Er,Cr:YSGG laser (erbium,chromium:yttrium-scandium-gallium-garnet) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.

3 findings from 1 review

Nd:YAG laser vs Placebo (placebo laser or placebo agent) or no treatment

Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation

Nd:YAG laser (neodymium-doped:yttrium-aluminum-garnet) showed no clear difference in changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.

3 findings from 1 review

Diode laser, near infrared (700 nm to 850 nm) vs Placebo (placebo laser or placebo agent) or no treatment

Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation

Diode laser, near infrared (700 nm to 850 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.

3 findings from 1 review

Diode laser, near infrared (850 nm to 980 nm) vs Placebo (placebo laser or placebo agent) or no treatment

Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation

Diode laser, near infrared (850 nm to 980 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.

2 findings from 1 review

Diode laser, visible red (630 nm to 700 nm) vs Placebo (placebo laser or placebo agent) or no treatment

Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation

Diode laser, visible red (630 nm to 700 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.

3 findings from 1 review