New renal parenchymal defects (scars and thinning) on IVP: unit of analysis (children) at 4 to 5 years: surgical correction + antibiotics versus antibiotics alone · primary VUR
Surgical reimplantation of ureters plus antibiotics showed no clear difference in new renal parenchymal defects (scars and thinning) on IVP: unit of… compared with antibiotics alone (moderate certainty).
1 finding from 1 review
Correction of VUR: unit of analysis (children) after 3 years: surgical correction + antibiotics versus antibiotics alone · primary VUR
It is very uncertain whether surgical reimplantation of ureters plus antibiotics changes correction of VUR: unit of analysis (children) after 3 years:… compared with antibiotics alone (very low certainty).
1 finding from 1 review
Number of participants with symptomatic UTI · primary VUR
Surgical reimplantation of ureters plus antibiotics showed no clear difference in all symptomatic UTI by 4 to 5 years: surgical correction +… compared with antibiotics alone (moderate certainty).
1 finding from 1 review
Febrile UTI by 5 years: surgical correction + antibiotics versus antibiotics alone · primary VUR
Surgical reimplantation of ureters plus antibiotics probably leads to lower febrile UTI by 5 years: surgical correction + antibiotics versus… compared with antibiotics alone (moderate certainty).
1 finding from 1 review
Repeat positive urine culture · primary VUR
Surgical reimplantation of ureters plus antibiotics showed no clear difference in repeat positive urine cultures by 4 to 5 years: surgical correction… compared with antibiotics alone (moderate certainty).
1 finding from 1 review
Patency at 30 days · thrombosed haemodialysis arteriovenous fistulas and grafts
It is very uncertain whether surgical thrombectomy changes patency at 30 days compared with pulse spray technique (very low certainty).
1 finding from 1 review
Failure · thrombosed haemodialysis arteriovenous fistulas and grafts
It is very uncertain whether surgical thrombectomy changes failure compared with mechanical thrombectomy (very low certainty).
1 finding from 1 review
Technical success · thrombosed haemodialysis arteriovenous fistulas and grafts
Surgical thrombectomy showed no clear difference in technical success compared with mechanical thrombectomy (low certainty).
1 finding from 1 review
Access dysfunction · thrombosed haemodialysis arteriovenous fistulas and grafts
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Successful dialysis · thrombosed haemodialysis arteriovenous fistulas and grafts
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Major adverse events · thrombosed haemodialysis arteriovenous fistulas and grafts
It is very uncertain whether surgical thrombectomy changes major adverse events compared with mechanical thrombectomy (very low certainty).
1 finding from 1 review
Minor adverse events · thrombosed haemodialysis arteriovenous fistulas and grafts
It is very uncertain whether surgical thrombectomy changes minor adverse events compared with mechanical thrombectomy (very low certainty).
1 finding from 1 review
Death · thrombosed haemodialysis arteriovenous fistulas and grafts
It is very uncertain whether surgical thrombectomy changes death compared with mechanical thrombectomy (very low certainty).
1 finding from 1 review
Failure · thrombosed haemodialysis arteriovenous fistulas and grafts
It is very uncertain whether surgical thrombectomy changes failure compared with pulse spray technique (very low certainty).
1 finding from 1 review
Technical success · thrombosed haemodialysis arteriovenous fistulas and grafts
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Patency at 30 days · thrombosed haemodialysis arteriovenous fistulas and grafts
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Failure · thrombosed haemodialysis arteriovenous fistulas and grafts
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Technical success · thrombosed haemodialysis arteriovenous fistulas and grafts
It is very uncertain whether surgical thrombectomy changes technical Success compared with continuous infusion (very low certainty).
1 finding from 1 review
Access dysfunction · thrombosed haemodialysis arteriovenous fistulas and grafts
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Successful dialysis · thrombosed haemodialysis arteriovenous fistulas and grafts
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found