Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

4 questions · 16 findings · 1 reviews · All outcomes

No studies found 0 · 0%GRADE not reported 16 · 100%Very low 0 · 0%Low 0 · 0%Moderate 0 · 0%High 0 · 0%

Laser fluorescence (DIAGNOdent 2095) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, laser fluorescence (DIAGNOdent 2095) pooled summary ROC AUC was 0.81 for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2095) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, laser fluorescence (DIAGNOdent 2095) pooled summary ROC AUC was 0.79 for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2095) vs Cavity preparation or biopsy (operative validation)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces

In in vivo, laser fluorescence (DIAGNOdent 2095) pooled diagnostic odds ratio was 18.33 (95% CI 7.57 to 44.37) for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2095) vs Cavity preparation or biopsy (operative validation)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces

In in vivo, laser fluorescence (DIAGNOdent 2095) pooled summary ROC AUC was 0.92 for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding