Digital bitewing radiography, sensor-based (CCD/CMOS) vs Histological validation of dental tissues (gold standard)
Diagnostic accuracy for proximal caries detection (dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)
Under in vitro conditions, sensor-based digital bitewing radiography had a pooled diagnostic odds ratio of 12.84 (95% CI 6.56, 25.13) for proximal caries detection at the dentin detection level; ungraded.
4 findings from 1 review
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Dentin detection levelDOR 12.84 [6.56, 25.13]4 studiesGRADE not reported
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Dentin detection levelSpecificity 0.95 [0.93, 0.97]4 studiesGRADE not reported
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Dentin detection levelAUC 0.904 studiesGRADE not reported
Show 1 more finding
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Dentin detection levelSensitivity 0.36 [0.30, 0.42]4 studiesGRADE not reported