Conventional bitewing radiography, F-speed film vs Histological validation of dental tissues (gold standard)
Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)
Under in vitro conditions, conventional F-speed bitewing radiography had a summary ROC AUC of 0.72 for proximal caries detection at the caries detection level; ungraded.
4 findings from 1 review
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Caries detection levelAUC 0.728 studiesGRADE not reported
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Caries detection levelSpecificity 0.88 [0.74, 0.95]8 studiesGRADE not reported
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Caries detection levelDOR 5.34 [2.55, 11.17]8 studiesGRADE not reported
Show 1 more finding
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Caries detection levelSensitivity 0.43 [0.31, 0.57]8 studiesGRADE not reported