Conventional bitewing radiography (E-speed film) vs Histological validation of dental tissues (gold standard)
Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)
Under in vitro conditions, conventional E-speed bitewing radiography had a pooled sensitivity of 0.42 (95% CI 0.28, 0.57) for proximal caries detection at the caries detection level; ungraded.
4 findings from 1 review
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Caries detection levelSensitivity 0.42 [0.28, 0.57]9 studiesGRADE not reported
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Caries detection levelSpecificity 0.90 [0.84, 0.93]9 studiesGRADE not reported
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Caries detection levelAUC 0.829 studiesGRADE not reported
Show 1 more finding
- Systematic review and meta-analysis of diagnostic studies of proximal surface caries. 2021 All outcomesIn vitro (laboratory; extracted teeth); permanent posterior teeth, proximal surfaces · Caries detection levelDOR 6.80 [4.58, 10.10]9 studiesGRADE not reported