Clinical stability of osteotomy segments (VAS 0 to 10) · Adults (>16 years old) undergoing orthognathic surgery
1 finding from 1 review
Clinical stability of osteotomy segments (Cheung 2004), self-assessed on a VAS (0=very mobile, 10=no mobility) by postoperative period, titanium vs resorbable mean (SD): 0 to 2 weeks 8.10 (1.79) vs 8.47 (2.18), P=0.48;…
1 study · 60 participants
GRADE not reported
Patient satisfaction (VAS 0 to 10) · Adults (>16 years old) undergoing orthognathic surgery
It is very uncertain whether resorbable (bioresorbable) plates or screws for fixation changes patient satisfaction (VAS 0 to 10) compared with titanium plates or screws for fixation (very low certainty).
1 finding from 1 review
Postoperative pain during the immediate recovery period (VAS 0 to 10) · Adults (>16 years old) undergoing orthognathic surgery
It is very uncertain whether resorbable (bioresorbable) plates or screws for fixation changes postoperative pain during the immediate recovery period (VAS 0 to 10) compared with titanium plates or screws for fixation (very low certainty).
1 finding from 1 review
Analgesic medication used (type, dose, frequency) · Adults (>16 years old) undergoing orthognathic surgery
The review found no eligible studies for this question.
1 finding from 1 review
Status of occlusion (e.g. ANB, Angle's classification, Wits analysis) · Adults (>16 years old) undergoing orthognathic surgery
1 finding from 1 review
Resorbable versus titanium plates for orthognathic surgery 2017 · Cochrane All outcomesUp to 3 years postoperatively
Weidner 2005 provided analyses of mean changes in ANB from scanned radiographs. The ANB data were incomplete for many of the five time periods and were reported as 'grad' rather than the conventionally accepted…
1 study · 43 participants
GRADE not reported
Need for retreatment or replacement of fixation due to failure of the fixation · Adults (>16 years old) undergoing orthognathic surgery
1 finding from 1 review
SoF row (Resorbable plates compared to titanium plates for stabilization after orthognathic surgery). Need for retreatment or replacement of fixation due to failure of the fixation (plates failed or removed in each…
1 study · 60 participants
Very low
Complications: chronic wound pain · Adults (>16 years old) undergoing orthognathic surgery
It is very uncertain whether resorbable (bioresorbable) plates or screws for fixation changes postoperative chronic or lasting pain (wound discomfort) at 4 to 6… compared with titanium plates or screws for fixation (very low certainty).
1 finding from 1 review
Facial appearance and profile · Adults (>16 years old) undergoing orthognathic surgery
The review found no eligible studies for this question.
1 finding from 1 review
Swelling (mean) · Adults (>16 years old) undergoing orthognathic surgery
1 finding from 1 review
Resorbable versus titanium plates for orthognathic surgery 2017 · Cochrane All outcomesUp to 3 years postoperatively
Though Cheung 2004 reported the presence of postoperative swelling, it was only noted in conjunction with infection and pus discharge; assessment of this outcome did not include the use of photography or digital…
1 study · 60 participants
GRADE not reported
Degree of function postoperatively (mastication, swallowing, speech) · Adults (>16 years old) undergoing orthognathic surgery
The review found no eligible studies for this question.
1 finding from 1 review
Satisfactory radiographic appearance (cephalometric radiographs) · Adults (>16 years old) undergoing orthognathic surgery
The review found no eligible studies for this question.
1 finding from 1 review