Proportion of eyes with final BCVA 20/40 or better at 6 months · people with simple rhegmatogenous retinal detachments
Pneumatic retinopexy may leads to higher proportion of eyes with final BCVA 20/40 or better at 6 months compared with scleral buckle (low certainty).
1 finding from 1 review
RR 1.31 [1.04, 1.65]
Studies not reported
Low
Any operative ocular adverse event at 6–24 months · people with simple rhegmatogenous retinal detachments
Pneumatic retinopexy showed no clear difference in any operative ocular adverse event at 6–24 months compared with scleral buckle (low certainty).
1 finding from 1 review
RR 0.55 [0.28, 1.11]
Studies not reported
Low
Quality of life · people with simple rhegmatogenous retinal detachments
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Failed trabeculectomy · People with glaucoma
The review found no eligible studies for this question.
2 findings from 1 review
Mean intraocular pressure · People with glaucoma
Fornix showed no clear difference in mean intraocular pressure compared with limbal‐based conjunctival trabeculectomy flaps (moderate certainty).
2 findings from 1 review
Visual acuity loss:defined as: loss of visual acuity equal to or greater than 0.3 LogMAR · People with glaucoma
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Mean number of medications needed after surgery · People with glaucoma
Fornix showed no clear difference in mean number of medications needed after surgery compared with limbal‐based conjunctival trabeculectomy flaps (high certainty).
1 finding from 1 review
Vision‐related quality of life · People with glaucoma
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Proportion of participants who were medication‐free (not using drops) at 12 months · people with open‐angle glaucoma
It is very uncertain whether phaco‐AIT changes proportion of participants who were medication‐free (not using… compared with phaco‐Trab (very low certainty).
1 finding from 1 review
Mean change in IOP measured in mmHg 12 months postintervention · people with open‐angle glaucoma
1 finding from 1 review
Mean change in number of IOP‐lowering drops from baseline · people with open‐angle glaucoma
1 finding from 1 review
Proportion needing additional glaucoma surgery at 1‐year · people with open‐angle glaucoma
It is very uncertain whether phaco‐AIT changes proportion of participants who required further glaucoma surgery at… compared with phaco‐Trab (very low certainty).
1 finding from 1 review
Rate of visual field progression · people with open‐angle glaucoma
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Mean change in health‐related quality of life · people with open‐angle glaucoma
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Intraoperative and postoperative complications · people with open‐angle glaucoma
1 finding from 1 review
no estimate extracted
8 participants
Very low
Nd:YAG capsulotomy at one year · patients undergoing cataract surgery
Sharp‐edged intraocular lens (IOL) showed no clear difference in nd:YAG capsulotomy at one year compared with round‐edged IOL (low certainty).
1 finding from 1 review
Posterior capsule opacification score at one year As measured by AQUA score, Evaluation of PCO (EPCO) score and other methods of quantifying PCO · patients undergoing cataract surgery
1 finding from 1 review
BCDVA · patients undergoing cataract surgery
1 finding from 1 review
Quality of life · patients undergoing cataract surgery
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Adverse effects · patients undergoing cataract surgery
It is very uncertain whether sharp‐edged intraocular lens (IOL) changes adverse effects compared with round‐edged IOL (very low certainty).
1 finding from 1 review
no estimate extracted
Studies not reported
Very low