Primary study · included by 1 review

Multilevel Combined Surgery With Transoral Robotic Surgery for Obstructive Sleep Apnea Syndrome.

Kayhan 2016 · Kayhan Fatma Tülin, Kaya Kamil Hakan, Koç Arzu Karaman, et al. · The Journal of craniofacial surgery · 2016

Included by

Robotic versus non-robotic posterior midline glossectomy for obstructive sleep apnea: a systematic review and meta-analysis.
Non-Cochrane · intervention · 2026 · cited as Kayhan 2016 · Supplementary Table 1; reference list; forest plots
Outcome this study informsPooled effectEvidenceCertainty
Apnea-hypopnea index (AHI), change
Robotic (TORS) posterior midline glossectomy vs None (single-arm pre/post change or absolute value) · Postoperative; mean follow-up 7.5 months in robotic studies
MD -25.93 [-31.82, -20.03]9 studiesGRADE not reported
Oxygen nadir (minimum oxygen saturation), change
Robotic (TORS) posterior midline glossectomy vs None (single-arm pre/post change or absolute value) · Postoperative; mean follow-up 7.5 months in robotic studies
MD 5.48 [2.21, 8.75]6 studiesGRADE not reported
Operative time
Robotic (TORS) posterior midline glossectomy vs None (single-arm pre/post change or absolute value) · Postoperative; mean follow-up 7.5 months in robotic studies
MEAN 50.26 [31.79, 68.73]3 studiesGRADE not reported
Oxygen nadir (minimum oxygen saturation), change
Posterior midline glossectomy, robotic and non-robotic combined vs None (single-arm pre/post change or absolute value) · Postoperative; follow-up varied
MD 7.42 [5.16, 9.69]23 studiesGRADE not reported
Surgical success rate (Sher criteria)
Robotic (TORS) posterior midline glossectomy vs None (single-arm pre/post change or absolute value) · Postoperative; mean follow-up 7.5 months in robotic studies
Proportion 0.64 [0.56, 0.73]9 studiesGRADE not reported
Surgical success rate (Sher criteria)
Posterior midline glossectomy, robotic and non-robotic combined vs None (single-arm pre/post change or absolute value) · Postoperative; follow-up varied
Proportion 0.61 [0.54, 0.69]22 studiesGRADE not reported
Apnea-hypopnea index (AHI), change
Posterior midline glossectomy, robotic and non-robotic combined vs None (single-arm pre/post change or absolute value) · Postoperative; follow-up varied
MD -25.33 [-29.86, -20.81]28 studiesGRADE not reported
Epworth Sleepiness Scale (ESS), change
Robotic (TORS) posterior midline glossectomy vs None (single-arm pre/post change or absolute value) · Postoperative; mean follow-up 7.5 months in robotic studies
MD -7.43 [-8.65, -6.21]9 studiesGRADE not reported
Epworth Sleepiness Scale (ESS), change
Posterior midline glossectomy, robotic and non-robotic combined vs None (single-arm pre/post change or absolute value) · Postoperative; follow-up varied
MD -6.32 [-7.94, -4.7]21 studiesGRADE not reported
Operative time
Posterior midline glossectomy, robotic and non-robotic combined vs None (single-arm pre/post change or absolute value) · Postoperative; follow-up varied
MEAN 49.34 [38.29, 60.4]6 studiesGRADE not reported

1 including review in total.