Primary study · included by 1 review
Treatment of obstructive sleep apnea-hypopnea syndrome with combined uvulopalatopharyngoplasty and midline glossectomy: outcomes from a 5-year study.
Hou 2012 · Hou Jin, Yan Jing, Wang Botao, et al. · Respiratory care · 2012
Included by
| Outcome this study informs | Pooled effect | Evidence | Certainty |
|---|---|---|---|
Oxygen nadir (minimum oxygen saturation), change Non-robotic posterior midline glossectomy (coblation, laser, radiofrequency or conventional) vs None (single-arm pre/post change or absolute value) · Postoperative; mean follow-up 13 months in non-robotic studies | MD 8.11 [5.06, 11.16] | 17 studies | GRADE not reported |
Oxygen nadir (minimum oxygen saturation), change Posterior midline glossectomy, robotic and non-robotic combined vs None (single-arm pre/post change or absolute value) · Postoperative; follow-up varied | MD 7.42 [5.16, 9.69] | 23 studies | GRADE not reported |
Apnea-hypopnea index (AHI), change Posterior midline glossectomy, robotic and non-robotic combined vs None (single-arm pre/post change or absolute value) · Postoperative; follow-up varied | MD -25.33 [-29.86, -20.81] | 28 studies | GRADE not reported |
Apnea-hypopnea index (AHI), change Non-robotic posterior midline glossectomy (coblation, laser, radiofrequency or conventional) vs None (single-arm pre/post change or absolute value) · Postoperative; mean follow-up 13 months in non-robotic studies | MD -24.99 [-30.97, -19.0] | 19 studies | GRADE not reported |
1 including review in total.