Primary study · included by 1 review

Treatment effects of intrusion arches and mini-implant systems in deepbite patients.

Senisik 2012 · Senışık Neslihan Ebru, Türkkahraman Hakan · American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2012

Included by

Outcome this study informsPooled effectEvidenceCertainty
Amount of incisor intrusion
Maxillary incisor intrusion with temporary anchorage devices (TADs/mini-implants) vs Connecticut intrusion arch (CTA)
SMD -1.02 [-1.79, -0.24]3 studies · 92 participantsGRADE not reported
Treatment duration
Maxillary incisor intrusion with temporary anchorage devices (TADs/mini-implants) vs Connecticut intrusion arch (CTA)
MD -0.13 [-0.64, 0.38]2 studies · 66 participantsVery low
Amount of incisor intrusion
Maxillary incisor intrusion with temporary anchorage devices (TADs/mini-implants) vs Connecticut intrusion arch (CTA)
SMD -0.88 [-1.35, -0.42]5 studies · 136 participantsLow
Overbite correction
Maxillary incisor intrusion with temporary anchorage devices (TADs/mini-implants) vs Connecticut intrusion arch (CTA)
SMD -0.48 [-1.02, 0.06]4 studies · 96 participantsLow

1 including review in total.