Non-Cochrane · intervention · PM42464084

The effect of surface treatment on the bonding properties of Polyetherketoneketone (PEKK) polymer to veneering materials: a systematic review and meta-analysis.

AlResayes Saad Saleh, Sayed Mohammed E, Qadi Khawla Ahmed, et al. · BMC oral health · 2026 · PubMed · doi:10.1186/s12903-026-09199-1

Findings

26 findings

Population
PEKK (Pekkton) specimens bonded to veneering composite resinAir abrasion with alumina (GAB)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · Air abrasion with alumina (GAB)
SMD 4.79 [2.24, 7.34]
Moderate
Downgraded: risk of bias
7 studies · 274 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinDiamond abrasionNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GDA
SMD -3.32 [-4.76, -1.87]
Moderate
Downgraded: risk of bias
1 study · 20 participants
PEKK (Pekkton) specimens bonded to veneering composite resinSulfuric acid etching (GAE)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · Sulfuric acid etching (GAE)
SMD 2.92 [0.4, 5.44]
Moderate
Downgraded: risk of bias
4 studies · 218 participants
PEKK (Pekkton) specimens bonded to veneering composite resinNon-thermal air plasma (GNTP)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · Non-thermal plasma (GNTP)
SMD 0.51 [-2.15, 3.18]
Moderate
Downgraded: risk of bias
2 studies · 62 participants
PEKK (Pekkton) specimens bonded to veneering composite resinTribochemical silica coating (GTCS)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · Tribochemical silica coating (GTCS)
SMD 1.74 [0.06, 3.42]
Moderate
Downgraded: risk of bias
3 studies · 162 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinAir abrasion plus sulfuric acid etchingNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GABAE
SMD 2.45 [1.63, 3.27]
Moderate
Downgraded: risk of bias
1 study · 42 participants
PEKK (Pekkton) specimens bonded to veneering composite resinTribochemical silica coating plus sulfuric acid etching (GTCSAE)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · Tribochemical silica coating + acid etching (GTCSAE)
SMD -0.39 [-0.72, -0.05]
Moderate
Downgraded: risk of bias
2 studies · 142 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinDiamond abrasion plus non-thermal plasmaNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GDANTP
SMD -3.85 [-5.44, -2.25]
Moderate
Downgraded: risk of bias
1 study · 20 participants
PEKK (Pekkton) specimens bonded to veneering composite resinAny surface pretreatment (all pretreatment subgroups combined)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · All pretreatments combined
SMD 1.08 [0.37, 1.8]
Moderate
Downgraded: risk of bias
10 studies · 1236 participants
PEKK (Pekkton) specimens bonded to veneering lithium disilicate ceramicAir abrasion with alumina (GAB)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · Air abrasion with alumina (GAB)
SMD 2.7 [1.16, 4.24]
Moderate
Downgraded: risk of bias
2 studies · 86 participants
PEKK (Pekkton) specimens bonded to veneering lithium disilicate ceramicSulfuric acid etching (GAE)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · Sulfuric acid etching (GAE)
SMD 1.75 [0.22, 3.27]
Moderate
Downgraded: risk of bias
2 studies · 86 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinTribochemical silica coating plus non-thermal plasmaNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GTCSNTP
SMD 2.01 [0.89, 3.12]
Moderate
Downgraded: risk of bias
1 study · 20 participants
PEKK (Pekkton) specimens bonded to veneering lithium disilicate ceramicAir abrasion plus sulfuric acid etching (GABAE)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · Air abrasion + sulfuric acid etching (GABAE)
SMD 1.37 [-1.71, 4.45]
Moderate
Downgraded: risk of bias
2 studies · 86 participants
PEKK (Pekkton) specimens bonded to veneering lithium disilicate ceramicAny surface pretreatment (all pretreatment subgroups combined)No surface pretreatment (control)Shear bond strength (MPa; some tensile or unspecified bond strength)
In vitro laboratory · All pretreatments combined
SMD 1.85 [0.96, 2.75]
Moderate
Downgraded: risk of bias
2 studies · 384 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinCold plasma (argon)No surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GCPA
SMD 1.81 [1.07, 2.56]
Moderate
Downgraded: risk of bias
1 study · 40 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinCold plasma (oxygen)No surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GCPO
SMD 0.56 [-0.08, 1.19]
Moderate
Downgraded: risk of bias
1 study · 40 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinCold plasma (nitrogen)No surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GCPN
SMD 1.51 [0.80, 2.22]
Moderate
Downgraded: risk of bias
1 study · 40 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinCold plasma (acetylene)No surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GCPAc
SMD 2.09 [1.30, 2.87]
Moderate
Downgraded: risk of bias
1 study · 40 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinHydroxyapatite coating (5%)No surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · HAP (5%)
SMD 19.04 [12.40, 25.68]
Moderate
Downgraded: risk of bias
1 study · 20 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinEr:YAG laser irradiationNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GEL
SMD -1.10 [-1.98, -0.23]
Moderate
Downgraded: risk of bias
1 study · 24 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinNd:YAG laser irradiationNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GNL
SMD -6.32 [-8.43, -4.21]
Moderate
Downgraded: risk of bias
1 study · 24 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinDiode laser irradiationNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GDL
SMD -5.41 [-7.27, -3.55]
Moderate
Downgraded: risk of bias
1 study · 24 participants
PEKK (polyetherketoneketone) specimens veneered with composite resinFemtosecond laser irradiationNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GFL
SMD -11.07 [-14.59, -7.55]
Moderate
Downgraded: risk of bias
1 study · 24 participants
PEKK (polyetherketoneketone) specimens veneered with lithium disilicate ceramicNon-thermal plasmaNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GNTP
SMD 0.00 [-0.60, 0.60]
Moderate
Downgraded: risk of bias
1 study · 42 participants
PEKK (polyetherketoneketone) specimens veneered with lithium disilicate ceramicTribochemical silica coatingNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GTCS
SMD 2.79 [1.92, 3.66]
Moderate
Downgraded: risk of bias
1 study · 42 participants
PEKK (polyetherketoneketone) specimens veneered with lithium disilicate ceramicTribochemical silica coating plus sulfuric acid etchingNo surface pre-treatment (control)Bond strength (shear, SMD)
Not specified · Laboratory (in vitro) · GTCSAE
SMD 2.42 [1.60, 3.23]
Moderate
Downgraded: risk of bias
1 study · 42 participants

Included primary studies 24

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Asik 2024
Effects of various laser applications on surface roughness and bond strength to veneering composites of polyether ether ketone (PEEK) and…
DOI:10.1007/s10103-024-04213-w
2024this review onlynot statednot extracted yet
Asik 2024
Effects of various laser applications on surface roughness and bond strength to veneering composites of polyether ether ketone (PEEK) and…
PMID:39500765
2024this review onlynot statednot extracted yet
Chopra 2023
To Evaluate and Compare the Effect of Various Surface Treatment Modalities on Shear Bond Strength of Composite to Polyetherketoneketone…
PMID:38075544
2023this review onlynot statednot extracted yet
Dede 2021
Influence of chairside surface treatments on the shear bond strength of PEKK polymer to veneering resin materials: An in vitro study.
PMID:33551138
2021this review onlynot statednot extracted yet
Demirci 2023
The effects of HAp coating layer on mechanical and optical properties at bonding interface of high-performance polymers
DOI:10.1016/j.jmbbm.2022.105539
2023this review onlynot statednot extracted yet
Demirci 2023
The effects of HAp coating layer on mechanical and optical properties at bonding interface of high-performance polymers.
PMID:36343522
2023this review onlynot statednot extracted yet
Fokas 2019
The effects of surface treatments on tensile bond strength of polyether-ketone-ketone (PEKK) to veneering resin
DOI:10.1016/j.jmbbm.2019.01.015
2019this review onlynot statednot extracted yet
Fokas 2019
The effects of surface treatments on tensile bond strength of polyether-ketone-ketone (PEKK) to veneering resin.
PMID:30738326
2019this review onlynot statednot extracted yet
Fuhrmann 2014
Resin bonding to three types of polyaryletherketones (PAEKs)—Durability and influence of surface conditioning
DOI:10.1016/j.dental.2013.12.008
2014this review onlynot statednot extracted yet
Fuhrmann 2014
Resin bonding to three types of polyaryletherketones (PAEKs)-durability and influence of surface conditioning.
PMID:24461250
2014this review onlynot statednot extracted yet
Goncalves 2025
Effect of Adhesive System on Bond Strength of Polyetheretherketone (PEEK) and Polyetherketoneketone (PEKK)
DOI:10.3390/jcs9040165
2025this review onlynot statednot extracted yet
Gouveia 2022
Effect of surface treatment and manufacturing process on the shear bond strength of veneering composite resin to polyetherketoneketone…
DOI:10.1016/j.prosdent.2021.02.003
2022this review onlynot statednot extracted yet
Gouveia 2022
Effect of surface treatment and manufacturing process on the shear bond strength of veneering composite resin to polyetherketoneketone…
PMID:33678435
2022this review onlynot statednot extracted yet
Kilic 2023
Comparing the shear bond strength of veneering materials to the PAEKs after surface treatments
DOI:10.1186/s12903-023-02879-2
2023this review onlynot statednot extracted yet
Kilic 2023
Comparing the shear bond strength of veneering materials to the PAEKs after surface treatments.
PMID:36997970
2023this review onlynot statednot extracted yet
Kocer 2024
matched by author and year (probable)
NRthis review onlynot statednot extracted yet
Lee 2017
Shear bond strength of composite resin to high performance polymer PEKK according to surface treatments and bonding materials.
PMID:29142642
2017this review onlynot statednot extracted yet
M 2020
The impact of non-thermal plasma on the adhesion of polyetherketoneketone (PEKK) to a veneering composite system
DOI:10.1016/j.jmbbm.2020.104065
2020this review onlynot statednot extracted yet
M 2020
The impact of non-thermal plasma on the adhesion of polyetherketoneketone (PEKK) to a veneering composite system.
PMID:32919258
2020this review onlynot statednot extracted yet
Ruse 2021
Strength and flexibility of lithium disilicate bonded to polyetherketoneketone
DOI:10.1016/j.prosdent.2021.10.008
2023this review onlynot statednot extracted yet
Ruse 2021
Strength and flexibility of lithium disilicate bonded to polyetherketoneketone.
PMID:34863577
2023this review onlynot statednot extracted yet
Sakihara 2018
Effects of sulfuric and vinyl sulfonic acid etchants on bond strength of resin composite to polyetherketoneketone
DOI:10.1007/s10266-018-0375-0
2018this review onlynot statednot extracted yet
Sakihara 2018
Effects of sulfuric and vinyl sulfonic acid etchants on bond strength of resin composite to polyetherketoneketone.
PMID:29978283
2019this review onlynot statednot extracted yet
Tekli 2022
Evaluation of the Bond Strength of Polyetherketoneketone to Dental Ceramic.
PMID:36562250
2022this review onlynot statednot extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationPEKK specimensPEKK (Pekkton Ivory, milled or pressed) specimens (n=15 in vitro studies)
InterventionSurface pre-treatmentDiamond abrasion, air abrasion with alumina, tribochemical silica coating, sulfuric acid, vinyl sulfonic acid, acetone, piranha solution, non-thermal plasma, cold plasmas, lasers, hydroxyapatite coating and combinations
ComparisonSpecimens with no surface treatmentNo surface pre-treatment
OutcomesShear bond strength; tensile bond strengthShear bond strength (14 studies); tensile bond strength (1 study)
Study designsHuman clinical studies and in vitro laboratory studies; English language original researchIn vitro studies only (n=15); 11 in meta-analysis
TimingNot specifiedAging from none to thermocycling up to 37,500 cycles

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedNoNoyes
4Comprehensive literature searchcriticalPartial YesPartial Yesyes
5Study selection in duplicateYesYesyes
6Data extraction in duplicateNoNoyes
7List of excluded studies with reasonscriticalYesPartial Yesno
8Included studies described in detailYesPartial Yesno
9Risk of bias assessed satisfactorilycriticalRCT: N/A · NRSI: NoNRSI: Partial Yes · RCT: Partial Yesno
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalRCT: N/A · NRSI: NoNRSI: No · RCT: Nono
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalNoNoyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowCritically Lowyes