Non-Cochrane · intervention · PM42390277

Clinical Outcomes of Bone-Anchored Versus Socket-Suspended Prostheses in Individuals With Transfemoral Amputation: A Systematic Review and Meta-Analysis of Two-Arm Comparative Studies.

Tan Sue Wei Janice, Low Wen Xian, Bretherton Chris · Orthopaedic surgery · 2026 · PubMed · doi:10.1111/os.70369

Findings

Population Individuals with transfemoral amputation (TFA)

13 findings

Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Hip range of motion: flexion-extension
Cross-sectional (single time point)
MD 16.95
Very low
Downgraded: risk of bias, imprecision, inconsistency
2 studies · 100 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Hip range of motion: abduction-adduction
Cross-sectional (single time point)
MD 4.1
Very low
Downgraded: risk of bias, imprecision
2 studies · 100 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Quality of life: Q-TFA global health
Cross-sectional (single time point)
MD 1.14 [-22.02, 24.30]
Very low
Downgraded: risk of bias, imprecision, inconsistency
3 studies · 96 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Mobility: 6-Minute Walk Test (6MWT)
Cross-sectional (single time point)
MD -65
Very low
Downgraded: risk of bias, imprecision
2 studies · 53 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Quality of life: Q-TFA prosthesis use
Cross-sectional (single time point)
MD 1.18 [-2.36, 4.71]
Very low
Downgraded: risk of bias, imprecision
4 studies · 112 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Gait: gait speed
Cross-sectional (single time point)
MD -0.03 [-0.31, 0.25]
Very low
Downgraded: risk of bias, imprecision
3 studies · 77 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Quality of life: Q-TFA problems
Cross-sectional (single time point)
MD -6.29 [-18.77, 6.19]
Very low
Downgraded: risk of bias, imprecision, inconsistency
3 studies · 96 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Mobility: Prosthetic Limb Users Survey of Mobility (PLUS-M)
Cross-sectional (single time point)
MD 0.34
Very low
Downgraded: risk of bias, imprecision
2 studies
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Mobility: Activities-specific Balance Confidence (ABC) scale
Cross-sectional (single time point)
MD 0.05 [-22.19, 22.29]
Very low
Downgraded: risk of bias, imprecision
3 studies · 58 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Quality of life: Q-TFA prosthetic mobility
Cross-sectional (single time point)
MD 0.37 [-9.93, 10.68]
Low
Downgraded: risk of bias, imprecision
3 studies · 96 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Hip range of motion: rotation
Cross-sectional (single time point)
MD 24.3
Very low
Downgraded: risk of bias, imprecision, inconsistency
2 studies · 100 participants
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Complications and infection
Cross-sectional (single time point)
no estimate extracted
No studies found
0 studies
Bone-anchored prostheses (BAP)Socket-suspended prostheses (SSP)Mobility: Timed Up and Go (TUG) test
Cross-sectional (single time point)
MD 0.16 [-2.09, 2.41]
Very low
Downgraded: risk of bias, imprecision
3 studies · 79 participants

Included primary studies 12

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Gailey 2023
Comparison of prosthetic mobility and balance in transfemoral amputees with bone-anchored prosthesis vs. socket prosthesis.
PMID:36701197
2023this review onlynot statednot extracted yet
Hagberg 2005
Socket versus bone-anchored trans-femoral prostheses: hip range of motion and sitting comfort.
PMID:16281724
2005this review onlynot statednot extracted yet
Haggstrom 2013
Comparison of prosthetic costs and service between osseointegrated and conventional suspended transfemoral prostheses.
PMID:22907950
2013this review onlynot statednot extracted yet
Haggstrom 2014
Vibrotactile evaluation: osseointegrated versus socket-suspended transfemoral prostheses.
PMID:24699977
2013this review onlynot statednot extracted yet
Kooiman 2023
Oxygen consumption and gait dynamics in transfemoral bone-anchored prosthesis users compared to socket-prosthesis users: A cross-sectional…
PMID:37075553
2023this review onlynot statednot extracted yet
Kooiman 2024
The influence of prosthetic suspension on gait and cortical modulations is persons with a transfemoral amputation: socket-suspended versus…
PMID:38454427
2024this review onlynot statednot extracted yet
Moller 2024
Cognitive load in individuals with a transfemoral amputation during single- and dual-task walking: a pilot study of brain activity in…
PMID:39175448
2024this review onlynot statednot extracted yet
Orgel 2022
Comparison of functional outcome and patient satisfaction between patients with socket prosthesis and patients treated with transcutaneous…
PMID:35717545
2022this review onlynot statednot extracted yet
Orgel 2023
Osseoperception in transcutaneous osseointegrated prosthetic systems (TOPS) after transfemoral amputation: a prospective study.
PMID:34345935
2023this review onlynot statednot extracted yet
Pospiech 2021
Quality of life of persons with transfemoral amputation: Comparison of socket prostheses and osseointegrated prostheses.
PMID:33834741
2021this review onlynot statednot extracted yet
Ranaldi 2023
Walking ability of individuals fitted with transfemoral bone-anchored prostheses: A comparative study of gait parameters.
PMID:37350084
2023this review onlynot statednot extracted yet
Welke 2023
Comparison of conventional socket attachment and bone-anchored prosthesis for persons living with transfemoral amputation - mobility and…
PMID:37075546
2023this review onlynot statednot extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationHumans over 18 years with unilateral or bilateral transfemoral amputationIndividuals with transfemoral amputation (BAP n=200; SSP n=244)
InterventionAny bone-anchored prosthesis (OPRA, OIP, TOPS, ILP)BAP: OPRA (n=5 studies), TOPS (n=3), ILP (n=1), OIP (n=1)
ComparisonSocket-suspended prosthesis usersSSP users
OutcomesQuality of life, mobility, gait analysis, hip range of motion, osseoperception, cost analysis, infectionMobility (6 studies), quality of life (5), gait (4), hip ROM (2), osseoperception (2), cost (1); no infection or complications studies
Study designsTwo-arm comparative studies only (cross-sectional, prospective cohort, retrospective, RCT or NRCT)12 cross-sectional two-arm comparative studies (non-randomized)
TimingSingle time point or follow-up periodsCross-sectional; time with BAP 2 to 16 years

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedYesYesyes
4Comprehensive literature searchcriticalPartial YesPartial Yesyes
5Study selection in duplicateYesYesyes
6Data extraction in duplicateNoYesno
7List of excluded studies with reasonscriticalNoNoyes
8Included studies described in detailPartial YesPartial Yesyes
9Risk of bias assessed satisfactorilycriticalNRSI: Yes · RCT: N/ANRSI: Yes · RCT: N/Ayes
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalNRSI: No · RCT: N/ANRSI: No · RCT: N/Ayes
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalNoNoyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowCritically Lowyes