Non-Cochrane · intervention · PM42251737

Effect of Fluorescent Adhesives on Visibility and Tooth Enamel Surface Properties After Debonding: A Systematic Review and Meta-Analysis.

Omidkhoda Maryam, Bardideh Erfan, Nowabadi Alireza, et al. · Clinical and experimental dental research · 2026 · PubMed · doi:10.1002/cre2.70385

Findings

Population Extracted human or bovine teeth undergoing orthodontic bracket bonding and debonding (in vitro)

7 findings

Fluorescent orthodontic adhesivesConventional non-fluorescent adhesivesShear bond strength (MPa)
After debonding · Laboratory · Human teeth only (bovine sample excluded)
MD 2.64 [-1.54, 6.82]
GRADE not reported
4 studies · 180 participants
Fluorescent orthodontic adhesivesConventional non-fluorescent adhesivesEnamel damage index (EDI)
After debonding · Laboratory
MD -0.04 [-0.28, 0.2]
Very low
Downgraded: risk of bias, imprecision, indirectness
3 studies · 108 participants
Fluorescent orthodontic adhesivesConventional non-fluorescent adhesivesAdhesive remnant index (ARI)
After debonding · Laboratory
MD 0.18 [-0.1, 0.46]
Very low
Downgraded: risk of bias, imprecision, inconsistency, indirectness
6 studies · 270 participants
Fluorescent orthodontic adhesivesConventional non-fluorescent adhesivesResidual adhesive surface area (mm2)
After debonding · Laboratory
MD -0.57 [-1.13, -0.02]
Very low
Downgraded: risk of bias, imprecision, inconsistency, indirectness
5 studies · 326 participants
Fluorescent orthodontic adhesivesConventional non-fluorescent adhesivesAdhesive remnant index (ARI)
After debonding · Laboratory · Human teeth only (bovine sample excluded)
MD 0.29 [0.04, 0.55]
GRADE not reported
5 studies · 238 participants
Fluorescent orthodontic adhesivesConventional non-fluorescent adhesivesAdhesive removal time (s)
After debonding · Laboratory
MD -24.89 [-50.29, 0.51]
Very low
Downgraded: risk of bias, imprecision, inconsistency, indirectness
6 studies · 348 participants
Fluorescent orthodontic adhesivesConventional non-fluorescent adhesivesShear bond strength (MPa)
After debonding · Laboratory
MD 1.07 [-3.05, 5.19]
Very low
Downgraded: risk of bias, imprecision, inconsistency, indirectness
5 studies · 212 participants

Included primary studies 19

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Albertini 2022
Fluorescence-aided removal of orthodontic composites: an in vivo comparative study.
PMID:35599253
2022this review onlynot statednot extracted yet
AlSamak 2023
Evaluation of the shear bond strength and adhesive remnant index of color change, fluorescent, and conventional orthodontic adhesives: An…
PMID:36493626
2023this review onlyShear bond strength (MPa); Adhesive remnant index (ARI)not extracted yet
Asokan 2024
matched by author and year (probable)
NRthis review onlyShear bond strength (MPa); Adhesive remnant index (ARI); Residual adhesive surface area (mm2); Enamel damage index (EDI); Adhesive removal time (s)not extracted yet
Chung 2024
Optimizing Ultraviolet Illumination for Detecting Fluorescent Orthodontic Adhesive Residues during Debonding Procedures.
PMID:38930329
2024this review onlynot statednot extracted yet
Engeler 2021
Fluorescence-Aided Identification Technique (FIT) Improves Tooth Surface Clean-Up after Debonding of Buccal and Lingual Orthodontic…
PMID:35011955
2021this review onlyResidual adhesive surface area (mm2)not extracted yet
Farronato 2021
Evaluation of Dental Surface after De-Bonding Orthodontic Bracket Bonded with a Novel Fluorescent Composite: In Vitro Comparative Study
DOI:10.3390/app11146354
2021this review onlyAdhesive remnant index (ARI); Adhesive removal time (s)not extracted yet
Kaneshima 2018
Using UV light for adhesive remnant removal after debonding of orthodontic accessories.
PMID:30281682
2018this review onlynot statednot extracted yet
Kim 2018
Detection of residual resin-based orthodontic adhesive based on light-induced fluorescence.
PMID:30179668
2018this review onlynot statednot extracted yet
Lai 2019
An in vitro comparison of ultraviolet versus white light in the detection of adhesive remnants during orthodontic debonding.
PMID:30653333
2019this review onlyResidual adhesive surface area (mm2); Adhesive removal time (s)not extracted yet
Moecke 2022
Efficacy of Bracket Adhesive Remnant Removal by a Fluorescence-Aided Identification Technique with a UV Light Handpiece: In Vitro Study.
PMID:36249726
2022this review onlyAdhesive removal time (s)not extracted yet
Namura 2010
Usefulness of orthodontic adhesive-containing fluorescent dye.
PMID:20466771
2010this review onlyShear bond strength (MPa); Adhesive remnant index (ARI)not extracted yet
Ribeiro 2017
Assessing adhesive remnant removal and enamel damage with ultraviolet light: An in-vitro study.
PMID:28153158
2017this review onlyEnamel damage index (EDI)not extracted yet
Rocha 2017
Efficacy of auxiliary devices for removal of fluorescent residue after bracket debonding.
PMID:28035838
2017this review onlynot statednot extracted yet
Rossato 2020
Do fluorescent agents alter the mechanical strength of orthodontic adhesives? An in vitro and clinical study.
PMID:32037477
2020this review onlyShear bond strength (MPa); Adhesive remnant index (ARI)not extracted yet
Schott 2018
A new Fluorescence-aided Identification Technique (FIT) for optimal removal of resin-based bracket bonding remnants after orthodontic…
PMID:30264058
2018this review onlynot statednot extracted yet
Stadler 2019
Evaluation of a Fluorescence-aided Identification Technique (FIT) to assist clean-up after orthodontic bracket debonding.
PMID:31206307
2019this review onlyResidual adhesive surface area (mm2); Adhesive removal time (s)not extracted yet
Wu 2023
Quantitative light-induced fluorescence enables effective detection of orthodontic adhesive residues in diverse environments.
PMID:37567330
2023this review onlynot statednot extracted yet
Yamagata 2018
DOI:10.11344/nano.10.53
NRthis review onlynot statednot extracted yet
Yan 2024
In vitro evaluation of an easy-to-remove orthodontic adhesive with photochromic property.
PMID:38052230
2024this review onlyShear bond strength (MPa); Adhesive remnant index (ARI); Residual adhesive surface area (mm2); Enamel damage index (EDI); Adhesive removal time (s)not extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationTeeth subjected to orthodontic bonding (in vitro or in vivo)Extracted human and bovine teeth and brackets; 17 in vitro and 2 in vivo studies (n=19); 11 in vitro studies in meta-analysis
InterventionOrthodontic adhesives containing fluorescent materialsFluorescent adhesives with UV, FIT or conventional illumination (n=19)
ComparisonConventional adhesives without fluorescent materialsConventional adhesives such as Transbond XT (n=19)
OutcomesEnamel loss, shear bond strength, adhesive remnant index, surface roughness, residual adhesive surface area, adhesive removal timeSBS (n=5), ARI (n=6), residual adhesive area (n=5), EDI (n=3), removal time (n=6)
Study designsLaboratory and clinical studies reporting quantitative data on at least one outcomeIn vitro studies (n=17) and in vivo studies (n=2); one study with in vitro and clinical phases
TimingNot specifiedAfter debonding

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedNoNoyes
4Comprehensive literature searchcriticalPartial YesPartial Yesyes
5Study selection in duplicateYesYesyes
6Data extraction in duplicateYesYesyes
7List of excluded studies with reasonscriticalNoNoyes
8Included studies described in detailPartial YesPartial Yesyes
9Risk of bias assessed satisfactorilycriticalRCT: Yes · NRSI: YesNRSI: Yes · RCT: Yesno
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalRCT: Yes · NRSI: N/ANRSI: Yes · RCT: Yesno
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalNoNoyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowCritically Lowyes