Non-Cochrane · intervention · PM41393586

Comparative Evaluation of the Marginal Fit of Zirconia and Polyetheretherketone Copings Fabricated Using Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) Technology: A Systematic Review and Meta-Analysis.

Harimkar Radha L, Jaiswal Niraja, Gangurde Arti P, et al. · Cureus · 2025 · PubMed · doi:10.7759/cureus.96664

Findings

Population Full-coverage dental copings on extracted teeth, typodont models or standardized dies (in vitro)

1 finding

PEEK copings fabricated with CAD/CAMZirconia copings fabricated with CAD/CAMMarginal fit (marginal gap, micrometers)
Laboratory (in vitro)
SMD 1.72 [-0.46, 3.9]
GRADE not reported
5 studies · 126 participants

Included primary studies 10

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Amalorpavam 2021
Comparison of Marginal Fit and Internal Adaptation of Copings Fabricated with Polyetheretherketone and Zirconia - An In vitro Study.
PMID:35017956
2021this review onlyMarginal fit (marginal gap, micrometers)not extracted yet
Attia 2019
matched by author and year (probable)
NRthis review onlynot statednot extracted yet
Attia 2019
Effect of different fabrication techniques on the marginal precision of polyetheretherketone single-crown copings.
PMID:32636071
2020this review onlynot statednot extracted yet
Chouksey 2023
In Vitro Evaluation of Marginal Adaptation of Polyether Ether Ketone and Zirconia Copings
DOI:10.4103/njcp.njcp_701_22
2023this review onlynot statednot extracted yet
Chouksey 2023
In Vitro Evaluation of marginal adaptation of polyether ether ketone and zirconia copings.
PMID:37470642
2023this review onlynot statednot extracted yet
Emad 2020
matched by author and year (probable)
NRthis review onlyMarginal fit (marginal gap, micrometers)not extracted yet
Emam 2023
Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture…
PMID:37559037
2023this review onlyMarginal fit (marginal gap, micrometers)not extracted yet
Jangade 2025
Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided…
PMID:39750015
2025this review onlyMarginal fit (marginal gap, micrometers)not extracted yet
Mahajan 2024
matched by author and year (probable)
NRthis review onlynot statednot extracted yet
Makky 2020
matched by author and year (probable)
NRthis review onlyMarginal fit (marginal gap, micrometers)not extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationIn vitro studies of full-coverage zirconia and PEEK copings on extracted human teeth, typodont models or standardized diesCopings on extracted teeth (n=4 studies) or typodont/resin/steel dies (n=4 studies); sample sizes 18 to 40
InterventionPEEK copings fabricated using CAD/CAMPEEK copings (CAD milled, pressed, pellets, granules) (n=8 studies)
ComparisonZirconia copings fabricated using CAD/CAMZirconia copings (n=8 studies)
OutcomesMarginal fit accuracy (micrometers)Marginal gap in micrometers (n=8 studies; 5 pooled)
Study designsIn vitro experimental studies; English full textsIn vitro experimental studies (n=8)
TimingNot specifiedNot specified