Cochrane · systematic review · CD015066

Hearing protection field attenuation estimation systems and associated training for reducing workers’ exposure to noise

Morata, TC, Gong, W, Tikka, C, et al. · Cochrane Database of Systematic Reviews · 2024 · Cochrane Library

WorkAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
10
current version
GRADE rated
5
No studies
5
Included studies
NR
No studies 5 · 50%Ungraded 0 · 0%Very low 0 · 0%Low 1 · 10%Moderate 4 · 40%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Effects of instructions versus no instructions for fit testing HPDs

Population: workers exposed to noise using earplugs
6 questions
OutcomeEffectEvidenceStatus / GRADE
PAR (dB) at short‐term
Effects of instructions vs no instructions
no estimate extracted1 study · 285 participantsModerate
Downgraded: imprecision
PAR (dB) at long‐term
Effects of instructions vs no instructions
no estimate extracted1 study · 103 participantsModerate
Downgraded: imprecision
PAR (dB) at immediate
Effects of instructions vs no instructions
no estimate extracted1 study · 100 participantsLow
Downgraded: risk of bias, imprecision
PAR pass rate (%)
Effects of instructions vs no instructions
no estimate extractedNRNo studies
Adverse effects
Effects of instructions vs no instructions
no estimate extractedNRNo studies
Proportion of workers who wear HPDs
Effects of instructions vs no instructions
no estimate extractedNRNo studies

Effects of extensive instructions versus simple instructions for fit testing HPDs

Population: workers exposed to noise using HPDs
4 questions
OutcomeEffectEvidenceStatus / GRADE
PAR (dB) ‐ Fit testing of foam earplugs (immediate)
Effects of extensive instructions vs simple instructions
no estimate extracted1 study · 321 participantsModerate
Downgraded: imprecision
PAR pass rate (%) ‐ Fit testing of foam earplugs (immediate)
Effects of extensive instructions vs simple instructions
RR 1.75 [1.44, 2.11]1 study · 321 participantsModerate
Downgraded: imprecision
Adverse effects
Effects of extensive instructions vs simple instructions
no estimate extractedNRNo studies
Proportion of workers who wear HPDs
Effects of extensive instructions vs simple instructions
no estimate extractedNRNo studies