Cochrane · systematic review · CD013512

Transepithelial versus epithelium‐off corneal crosslinking for progressive keratoconus

Ng, SM, Ren, M, Lindsley, KB, et al. · Cochrane Database of Systematic Reviews · 2021 · Cochrane Library

Eyes and VisionAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
16
current version
GRADE rated
14
No studies
2
Included studies
NR
No studies 2 · 12.5%Ungraded 0 · 0%Very low 11 · 68.8%Low 2 · 12.5%Moderate 1 · 6.3%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Transepithelial CXL compared with epithelium‐off CXL for progressive keratoconus

Population: participants with keratoconus
8 questions
OutcomeEffectEvidenceStatus / GRADE
Mean change in maximum K from baseline or final value—at 12 months or more (diopters)
Transepithelial CXL vs epithelium‐off CXL
no estimate extracted5 studies · 177 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants whose maximum K decreased by at least 2 diopters—at 12 months
Transepithelial CXL vs epithelium‐off CXL
RR 0.32 [0.09, 1.12]1 study · 61 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants whose maximum K increased by at least 2 diopters—at 12 months
Transepithelial CXL vs epithelium‐off CXL
no estimate extracted1 study · 61 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants whose keratoconus remained stable—at 12 months
Transepithelial CXL vs epithelium‐off CXL
no estimate extracted2 studies · 131 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Mean change in corrected distance visual acuity (logMAR) from baseline or final values—at 12 months or more
Transepithelial CXL vs epithelium‐off CXL
no estimate extracted4 studies · 137 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants who gained 10 or more logMAR letters from baseline
Transepithelial CXL vs epithelium‐off CXL
no estimate extractedNRNo studies
Proportion of participants who lost 10 or more logMAR letters from baseline
Transepithelial CXL vs epithelium‐off CXL
no estimate extractedNRNo studies
Adverse outcomes—corneal haze or scarring
Transepithelial CXL vs epithelium‐off CXL
no estimate extracted4 studies · 221 participantsModerate
Downgraded: risk of bias

Transepithelial CXL using iontophoresis compared with epithelium‐off CXL for progressive keratoconus

Population: participants with progressive keratoconus
8 questions
OutcomeEffectEvidenceStatus / GRADE
Mean change in maximum K from baseline or final value—at 12 months or more (diopters)
Transepithelial CXL using iontophoresis vs epithelium‐off CXL
no estimate extracted2 studies · 51 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants whose maximum K decreased by at least 2 diopters—at 24 months
Transepithelial CXL using iontophoresis vs epithelium‐off CXL
no estimate extracted1 study · 31 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants whose maximum K increased by at least 2 diopters—at 24 months
Transepithelial CXL using iontophoresis vs epithelium‐off CXL
no estimate extracted1 study · 31 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants whose keratoconus remained stable—at 24 months
Transepithelial CXL using iontophoresis vs epithelium‐off CXL
RR 0.92 [0.76, 1.12]1 study · 31 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Mean change in corrected distance visual acuity (logMAR) from baseline or final values at 12 months or more
Transepithelial CXL using iontophoresis vs epithelium‐off CXL
no estimate extracted2 studies · 51 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants who gained 10 or more logMAR letters from baseline
Transepithelial CXL using iontophoresis vs epithelium‐off CXL
RR 2.73 [0.36, 20.74]1 study · 34 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants who lost 10 or more logMAR letters from baseline
Transepithelial CXL using iontophoresis vs epithelium‐off CXL
RR 1 [0.88, 1.13]1 study · 34 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Adverse outcomes
Transepithelial CXL using iontophoresis vs epithelium‐off CXL
no estimate extracted3 studies · 203 participantsLow
Downgraded: risk of bias, imprecision, inconsistency