Cochrane · systematic review · CD013244

Blue‐light filtering spectacle lenses for visual performance, sleep, and macular health in adults

Singh, S, Keller, PR, Busija, L, et al. · Cochrane Database of Systematic Reviews · 2023 · Cochrane Library

Eyes and VisionAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
7
current version
GRADE rated
5
No studies
2
Included studies
NR
No studies 2 · 28.6%Ungraded 0 · 0%Very low 1 · 14.3%Low 3 · 42.9%Moderate 1 · 14.3%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Summary of findings 1: blue‐light filtering lenses compared to non‐blue‐light filtering lenses

Population: adults
7 questions
OutcomeEffectEvidenceStatus / GRADE
Visual fatigue score, measured using a Likert scale or VAS, with
Summary of findings 1: blue‐light filtering lenses vs non‐blue‐light filtering lenses
no estimate extracted1 study · 120 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
CFF, measured in Hz, with a
Summary of findings 1: blue‐light filtering lenses vs non‐blue‐light filtering lenses
no estimate extracted1 study · 120 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
BCVA, measured in log units, with
Summary of findings 1: blue‐light filtering lenses vs non‐blue‐light filtering lenses
no estimate extracted1 study · 156 participantsModerate
Downgraded: risk of bias, imprecision, inconsistency
Proportion of eyes or individuals that developed macular structural changes
Summary of findings 1: blue‐light filtering lenses vs non‐blue‐light filtering lenses
no estimate extractedNRNo studies
Colour discrimination, measured using the FM‐100 hue test
Summary of findings 1: blue‐light filtering lenses vs non‐blue‐light filtering lenses
no estimate extractedNRNo studies
Subjective sleep scores, measured using a VAS or Likert scale, with
Summary of findings 1: blue‐light filtering lenses vs non‐blue‐light filtering lenses
no estimate extracted6 studies · 148 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Proportion of participants with adverse events with a probable causal linked with the study intervention
Summary of findings 1: blue‐light filtering lenses vs non‐blue‐light filtering lenses
no estimate extracted9 studies · 333 participantsLow
Downgraded: risk of bias, imprecision, inconsistency