Drug‐eluting balloon angioplasty versus uncoated balloon angioplasty for the treatment of in‐stent restenosis of the femoropopliteal arteries

Kayssi, A, Al‐Jundi, W, Papia, G, et al. · Cochrane Database of Systematic Reviews · 2019 · Cochrane Library

VascularAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
5
current version
GRADE rated
5
No studies
0
Included studies
NR
No studies 0 · 0%Ungraded 0 · 0%Very low 5 · 100%Low 0 · 0%Moderate 0 · 0%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Drug‐eluting balloon angioplasty at 6 months compared to uncoated balloon angioplasty at 6 months for in‐stent restenosis of the femoropopliteal arteries

Population: patients with in‐stent restenosis of the femoropopliteal arteries
5 questions
OutcomeEffectEvidenceStatus / GRADE
Amputation
Drug‐eluting balloon angioplasty at 6 months vs uncoated balloon angioplasty at 6 months
no estimate extracted3 studies · 263 participantsVery low
Downgraded: risk of bias, imprecision
Target lesion revascularization (TLR)
Drug‐eluting balloon angioplasty at 6 months vs uncoated balloon angioplasty at 6 months
OR 0.05 [0, 0.92]1 study · 70 participantsVery low
Downgraded: risk of bias, imprecision
Binary restenosis
Drug‐eluting balloon angioplasty at 6 months vs uncoated balloon angioplasty at 6 months
OR 0.28 [0.14, 0.56]2 studies · 189 participantsVery low
Downgraded: risk of bias, imprecision
Death
Drug‐eluting balloon angioplasty at 6 months vs uncoated balloon angioplasty at 6 months
OR 0.93 [0.13, 6.71]3 studies · 263 participantsVery low
Downgraded: risk of bias, imprecision
Improvement ≥ 1 Rutherford category
Drug‐eluting balloon angioplasty at 6 months vs uncoated balloon angioplasty at 6 months
OR 1.81 [1.02, 3.21]2 studies · 193 participantsVery low
Downgraded: risk of bias, imprecision