Cochrane · systematic review · CD009667

Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery

Ong, HS, Evans, JR, Allan, BDS · Cochrane Database of Systematic Reviews · 2014 · Cochrane Library

Eyes and VisionAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
7
current version
GRADE rated
7
No studies
0
Included studies
NR
No studies 0 · 0%Ungraded 0 · 0%Very low 1 · 14.3%Low 5 · 71.4%Moderate 1 · 14.3%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Comparison

Population: Participants over age of 21 years undergoing cataract surgery
7 questions
OutcomeEffectEvidenceStatus / GRADE
Distance‐corrected near visual acuity at 6 months [Jaeger units]
no estimate extracted2 studies · 106 participantsModerate
Downgraded: risk of bias, imprecision, inconsistency, indirectness
Distance‐corrected near visual acuity at 12 months or more [Jaeger units and logMAR units]
no estimate extracted111 participantsLow
Downgraded: risk of bias, imprecision, inconsistency, indirectness
Corrected distant visual acuity at 6 months [standard deviations]
no estimate extracted2 studies · 106 participantsLow
Downgraded: risk of bias, imprecision, inconsistency, indirectness
Corrected distant visual acuity at 12 months or more [logMAR units]
no estimate extracted2 studies · 70 participantsLow
Downgraded: risk of bias, imprecision, inconsistency, indirectness
Reading speed [words per minute]
no estimate extracted1 study · 40 participantsLow
Downgraded: risk of bias, imprecision, inconsistency, indirectness
Spectacle independence
RR 8.181 study · 40 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency, indirectness
Reported complications Laser capsulotomies for posterior capsule opacification (PCO)
Peto OR 7.962 studies · 60 participantsLow
Downgraded: risk of bias, imprecision, inconsistency, indirectness