Cochrane · systematic review · CD006947

Internal versus external tocodynamometry during induced or augmented labour

Bakker, JJH, Janssen, PF, van Halem, K, et al. · Cochrane Database of Systematic Reviews · 2013 · Cochrane Library

Pregnancy and Childbirth2 versionsAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
7
current version
GRADE rated
7
No studies
0
Included studies
NR
No studies 0 · 0%Ungraded 0 · 0%Very low 0 · 0%Low 0 · 0%Moderate 7 · 100%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Current version only

Monitoring of contractions with internal tocodynamometry compared to external tocodynamometry

CD006947.PUB3 (current) · 7 questions
OutcomeEffectEvidenceStatus / GRADE
Hyperstimulation
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.21 [0.78, 1.88]2 studies · 489 participantsModerate
Downgraded: risk of bias
Apgar score less than seven at five minutes
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.78 [0.83, 3.83]3 studies · 1945 participantsModerate
Downgraded: risk of bias
Umbilical artery pH < 7.15
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.31 [0.95, 1.79]1 study · 1456 participantsModerate
Downgraded: risk of bias
Umbilical artery pH < 7.16
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.23 [0.39, 3.92]1 study · 239 participantsModerate
Downgraded: risk of bias
Admission to neonatal intensive care
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 0.34 [0.07, 1.67]2 studies · 489 participantsModerate
Downgraded: risk of bias
Instrumental vaginal delivery
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.06 [0.85, 1.32]3 studies · 1945 participantsModerate
Downgraded: risk of bias
Caesarean section
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.04 [0.85, 1.29]3 studies · 1945 participantsModerate
Downgraded: risk of bias

Monitoring of contractions with internal tocodynamometry compared to external tocodynamometry

CD006947.PUB2 · 7 questions
OutcomeEffectEvidenceStatus / GRADE
Hyperstimulation
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.21 [0.78, 1.88]2 studies · 489 participantsModerate
Downgraded: risk of bias
Apgar score less than seven at five minutes
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.78 [0.83, 3.83]3 studies · 1945 participantsModerate
Downgraded: risk of bias
Umbilical artery pH < 7.15
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.31 [0.95, 1.79]1 study · 1456 participantsModerate
Downgraded: risk of bias
Umbilical artery pH < 7.16
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.23 [0.39, 3.92]1 study · 239 participantsModerate
Downgraded: risk of bias
Admission to neonatal intensive care
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 0.34 [0.07, 1.67]2 studies · 489 participantsModerate
Downgraded: risk of bias
Instrumental vaginal delivery
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.06 [0.85, 1.32]3 studies · 1945 participantsModerate
Downgraded: risk of bias
Caesarean section
Monitoring of contractions with internal tocodynamometry vs external tocodynamometry
RR 1.04 [0.85, 1.29]3 studies · 1945 participantsModerate
Downgraded: risk of bias