Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

22 questions · 22 findings · 1 reviews

No studies found 12 · 54.5%GRADE not reported 0 · 0%Very low 9 · 40.9%Low 1 · 4.5%Moderate 0 · 0%High 0 · 0%

Bakri balloon tamponade+traction stitch vs Bakri balloon (one intrauterine tamponade compared to another intrauterine tamponade technique)

Hysterectomy to control bleeding · women with primary atonic postpartum haemorrhage

It is very uncertain whether bakri balloon tamponade+traction stitch changes hysterectomy to control bleeding compared with bakri balloon (one intrauterine tamponade compared to another… (very low certainty).

1 finding from 1 review

Bakri balloon tamponade+traction stitch vs Bakri balloon (one intrauterine tamponade compared to another intrauterine tamponade technique)

Serious maternal morbidity (renal or respiratory failure, cardiac arrest or multiple organ failure) · women with primary atonic postpartum haemorrhage

The review found no eligible studies for this question.

1 finding from 1 review

Bakri balloon tamponade+traction stitch vs Bakri balloon (one intrauterine tamponade compared to another intrauterine tamponade technique)

Number of women with total blood loss 1000 mL or more after randomisation · women with primary atonic postpartum haemorrhage

The review found no eligible studies for this question.

1 finding from 1 review

Bakri balloon tamponade+traction stitch vs Bakri balloon (one intrauterine tamponade compared to another intrauterine tamponade technique)

Side effects of the intervention (e.g. trauma, necrosis) · women with primary atonic postpartum haemorrhage

The review found no eligible studies for this question.

1 finding from 1 review

Bakri balloon tamponade+traction stitch vs Bakri balloon (one intrauterine tamponade compared to another intrauterine tamponade technique)

Blood loss > 1000 mL · women with primary atonic postpartum haemorrhage

Bakri balloon tamponade+traction stitch showed no clear difference in total blood loss >= 1000 mL (before and after randomisation, outcome… compared with bakri balloon (one intrauterine tamponade compared to another… (low certainty).

1 finding from 1 review

Bakri balloon tamponade vs haemostatic square suturing to the lower segment of the uterus (intrauterine tamponade versus another mechanical/surgical method)

Serious maternal morbidity (renal or respiratory failure, cardiac arrest or multiple organ failure) · women with complete placenta praevia and intractable bleeding following caesarean section
1 finding from 1 review

Bakri balloon tamponade vs haemostatic square suturing to the lower segment of the uterus (intrauterine tamponade versus another mechanical/surgical method)

Number of women with total blood loss 1000 mL or more after randomisation · women with complete placenta praevia and intractable bleeding following caesarean section

The review found no eligible studies for this question.

1 finding from 1 review

Bakri balloon tamponade vs haemostatic square suturing to the lower segment of the uterus (intrauterine tamponade versus another mechanical/surgical method)

Blood transfusion (red cell or whole blood) · women with complete placenta praevia and intractable bleeding following caesarean section

It is very uncertain whether bakri balloon tamponade changes blood transfusion (red cell or whole blood) compared with haemostatic square suturing to the lower segment of the uterus… (very low certainty).

1 finding from 1 review

Bakri balloon tamponade vs haemostatic square suturing to the lower segment of the uterus (intrauterine tamponade versus another mechanical/surgical method)

Side effects of the intervention (e.g. trauma, necrosis) · women with complete placenta praevia and intractable bleeding following caesarean section
1 finding from 1 review

Bakri balloon tamponade vs condom‐loaded Foley Catheter (one intrauterine tamponade compared to another intrauterine tamponade technique)

Hysterectomy to control bleeding · women with primary atonic postpartum haemorrhage following vaginal delivery

It is very uncertain whether bakri balloon tamponade changes hysterectomy to control bleeding compared with condom‐loaded Foley Catheter (one intrauterine tamponade compared to… (very low certainty).

1 finding from 1 review

Bakri balloon tamponade vs condom‐loaded Foley Catheter (one intrauterine tamponade compared to another intrauterine tamponade technique)

Serious maternal morbidity (renal or respiratory failure, cardiac arrest or multiple organ failure) · women with primary atonic postpartum haemorrhage following vaginal delivery

The review found no eligible studies for this question.

1 finding from 1 review

Bakri balloon tamponade vs condom‐loaded Foley Catheter (one intrauterine tamponade compared to another intrauterine tamponade technique)

Number of women with total blood loss 1000 mL or more after randomisation · women with primary atonic postpartum haemorrhage following vaginal delivery

The review found no eligible studies for this question.

1 finding from 1 review

Bakri balloon tamponade vs condom‐loaded Foley Catheter (one intrauterine tamponade compared to another intrauterine tamponade technique)

Mean blood loss (mL) (trialist defined) · women with primary atonic postpartum haemorrhage following vaginal delivery

The review found no eligible studies for this question.

1 finding from 1 review