Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

137 questions · 148 findings · 7 reviews · Anaesthesia

No studies found 44 · 29.7%GRADE not reported 19 · 12.8%Very low 32 · 21.6%Low 38 · 25.7%Moderate 14 · 9.5%High 1 · 0.7%

0.5% bupivacaine, 1:200,000 epinephrine vs 2% lidocaine, 1:100,000 epinephrine

Speed of onset of anaesthesia · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
1 finding from 1 review

4% prilocaine plain vs 2% lidocaine, 1:100,000 epinephrine

Speed of onset of anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

4% prilocaine plain showed no clear difference in speed of onset of anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (low certainty).

1 finding from 1 review

0.5% bupivacaine, 1:200,000 epinephrine vs 2% lidocaine, 1:100,000 epinephrine

Duration of anaesthesia (soft tissue, simulated) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

It is very uncertain whether 0.5% bupivacaine, 1:200,000 epinephrine changes duration of anaesthesia (soft tissue, simulated) compared with 2% lidocaine, 1:100,000 epinephrine (very low certainty).

1 finding from 1 review

4% articaine, 1:100,000 epinephrine vs 2% lidocaine, 1:100,000 epinephrine

Duration of anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

It is very uncertain whether 4% articaine, 1:100,000 epinephrine changes duration of anaesthesia (pulpal, electric pulp tester; healthy pulps) compared with 2% lidocaine, 1:100,000 epinephrine (very low certainty).

1 finding from 1 review

3% mepivacaine plain vs 2% lidocaine, 1:100,000 epinephrine

Speed of onset of anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

3% mepivacaine plain may leads to lower speed of onset of anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (low certainty).

1 finding from 1 review

2% mepivacaine, 1:100,000 epinephrine vs 2% lidocaine, 1:100,000 epinephrine

Adverse effects: pain following injection · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

The review found no eligible studies for this question.

2 findings from 1 review

4% prilocaine plain vs 2% lidocaine, 1:100,000 epinephrine

Adverse effects: paraesthesia following injection · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

The review found no eligible studies for this question.

1 finding from 1 review
  • SoF: See comment; 0 participants (0 studies); 1 case of prolonged anaesthesia recorded; no clinical studies met the outcome definition (unable to confirm whether prolonged anaesthesia = paraesthesia).
    0 studies
    No studies found

4% articaine plain vs 4% articaine, 1:100,000 epinephrine

Duration of anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

It is very uncertain whether 4% articaine plain changes duration of anaesthesia (pulpal, electric pulp tester; healthy pulps) compared with 4% articaine, 1:100,000 epinephrine (very low certainty).

1 finding from 1 review

2% lidocaine, 1:50,000 epinephrine vs 2% lidocaine, 1:100,000 epinephrine

Speed of onset of anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

It is very uncertain whether 2% lidocaine, 1:50,000 epinephrine changes speed of onset of anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (very low certainty).

1 finding from 1 review

0.5% bupivacaine, 1:200,000 epinephrine vs 2% lidocaine, 1:100,000 epinephrine

Speed of onset of anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

0.5% bupivacaine, 1:200,000 epinephrine may leads to higher speed of onset of anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (low certainty).

1 finding from 1 review

4% articaine, 1:200,000 epinephrine vs 0.5% bupivacaine, 1:200,000 epinephrine

Speed of onset of anaesthesia (soft tissue, simulated) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

It is very uncertain whether 4% articaine, 1:200,000 epinephrine changes speed of onset of anaesthesia (soft tissue, simulated) compared with 0.5% bupivacaine, 1:200,000 epinephrine (very low certainty).

1 finding from 1 review

4% articaine, 1:200,000 epinephrine vs 2% lidocaine, 1:100,000 epinephrine

Speed of onset of anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…

It is very uncertain whether 4% articaine, 1:200,000 epinephrine changes speed of onset of anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (very low certainty).

1 finding from 1 review