Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

227 questions · 239 findings · 17 reviews · Orthodontics

No studies found 54 · 22.6%GRADE not reported 122 · 51%Very low 37 · 15.5%Low 19 · 7.9%Moderate 7 · 2.9%High 0 · 0%

NiTi arch wire of one cross-sectional size vs NiTi arch wire of a different cross-sectional size

Pain · People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
1 finding from 1 review
  • Different sizes of NiTi wires (Alhaija 2021; Erdinc 2004); not pooled due to clinical heterogeneity; little or no difference at day 1. Erdinc 0.014 vs 0.016 inch higher pain at day 4 MD 5.00 (0.19 to 9.81) and day 6 MD…
    2 studies · 149 participants
    Low

Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional (stabilised) NiTi arch wire

Alignment rate · People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)

It is very uncertain whether thermoelastic copper NiTi (CuNiTi) arch wire changes alignment rate compared with conventional NiTi arch wire (very low certainty).

1 finding from 1 review

Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire

Pain day 1 · People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)

Superelastic NiTi arch wire showed no clear difference in pain day 1 compared with conventional (stabilised) NiTi arch wire (low certainty).

1 finding from 1 review

Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire

Time to next/working arch wire · People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)

Superelastic NiTi arch wire showed no clear difference in time to next/working arch wire compared with conventional (stabilised) NiTi arch wire; GRADE not reported.

1 finding from 1 review

Fixed orthodontic treatment with fixed (multibracket) appliances (exposure) vs None (single-group prevalence/incidence estimate)

Association between orthodontic treatment duration and ICLs incidence · Patients undergoing fixed orthodontic treatment with fixed (multibracket) appliances, followed for development of new ICLs

ICLs incidence increased with longer orthodontic treatment duration (meta-regression P<.01; ungraded).

1 finding from 1 review

Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional (stabilised) NiTi arch wire

Time to alignment · People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)

Thermoelastic copper NiTi (CuNiTi) arch wire showed no clear difference in time to alignment (alignment rate ratio) compared with conventional NiTi arch wire (low certainty).

1 finding from 1 review

Superelastic NiTi arch wire vs Titanium-niobium-tantalum-zirconium (TiNbTaZr) arch wire

Alignment rate · People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
1 finding from 1 review

Coated superelastic NiTi wire (BioCosmetic, Titanol, TP Aesthetic or Tooth Tone) vs A different coated superelastic NiTi wire

Alignment rate · People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
1 finding from 1 review

Multistrand stainless steel wire vs Wires of other materials (conventional stainless steel, superelastic NiTi, thermoelastic NiTi)

Alignment rate · People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
1 finding from 1 review
  • Initial arch wires used in orthodontic treatment with fixed appliances 2024 · Cochrane All outcomes
    6 weeks to 6 months
    Multistrand StSt versus other materials (conventional StSt, superelastic NiTi, thermoelastic NiTi); alignment rate not pooled due to clinical heterogeneity (Cobb 1998; Evans 1998; Quintao 2005; West 1995); results…
    4 studies · 281 participants
    Very low