Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

6 questions · 6 findings · 3 reviews · Pregnancy and Childbirth

No studies found 3 · 50%GRADE not reported 0 · 0%Very low 2 · 33.3%Low 1 · 16.7%Moderate 0 · 0%High 0 · 0%

Oral misoprostol vs intravenous (IV) oxytocin

Uterine hyperstimulation with fetal heart rate changes · women in the third trimester for induction of labour.

It is very uncertain whether oral misoprostol changes uterine hyperstimulation with fetal heart rate changes compared with intravenous oxytocin (very low certainty).

1 finding from 1 review

Foley catheter vs intravenous (IV) oxytocin

Uterine hyperstimulation with fetal heart rate changes · pregnant women with a previous low transverse caesarean section, singleton live pregnancy with cephalic presentation, period of gestation…

Foley catheter showed no clear difference in uterine hyperstimulation with fetal heart rate changes compared with intravenous (IV) oxytocin (low certainty).

1 finding from 1 review

Oral misoprostol vs intravenous (IV) oxytocin

Uterine hyperstimulation without fetal heart rate changes · women in the third trimester for induction of labour.

It is very uncertain whether oral misoprostol changes uterine hyperstimulation without fetal heart rate changes compared with intravenous oxytocin (very low certainty).

1 finding from 1 review