Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
4% prilocaine plain showed no clear difference in success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
It is very uncertain whether 4% articaine plain changes success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 4% articaine, 1:200,000 epinephrine (very low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
It is very uncertain whether 2% lidocaine, 1:50,000 epinephrine changes success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (very low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
It is very uncertain whether 4% articaine plain changes success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 4% articaine, 1:100,000 epinephrine (very low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
3% mepivacaine plain showed no clear difference in success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:50,000 epinephrine (low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
It is very uncertain whether 4% articaine, 1:200,000 epinephrine changes success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 4% prilocaine, 1:200,000 epinephrine (very low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
It is very uncertain whether 2% lidocaine, 1:200,000 epinephrine changes success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (very low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
3% mepivacaine plain showed no clear difference in success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
4% articaine, 1:100,000 epinephrine may leads to higher success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
It is very uncertain whether 4% articaine, 1:200,000 epinephrine changes success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (very low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
It is very uncertain whether 2% lidocaine, 1:50,000 epinephrine changes success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:80,000 epinephrine (very low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
It is very uncertain whether 2% lidocaine, 1:80,000 epinephrine changes success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (very low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
4% prilocaine, 1:200,000 epinephrine may leads to higher success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 4% articaine, 1:100,000 epinephrine (low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
4% articaine, 1:200,000 epinephrine showed no clear difference in success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 4% articaine, 1:100,000 epinephrine (low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
0.5% bupivacaine, 1:200,000 epinephrine showed no clear difference in success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (low certainty).
1 finding from 1 review
Success of local anaesthesia (pulpal, electric pulp tester; healthy pulps) · Participants of any age and gender undergoing dental procedures, and volunteers who took part in simulated scenario studies in which…
4% prilocaine, 1:200,000 epinephrine showed no clear difference in success of local anaesthesia (pulpal, electric pulp tester; healthy… compared with 2% lidocaine, 1:100,000 epinephrine (low certainty).
1 finding from 1 review