3-dimensional (3D) miniplates vs Standard (Champy) plates
Post-operative adverse events and complications · Adults (16 to 68 years) with mandibular fractures excluding condylar involvement
1 finding from 1 review
- Jain 2010 (3D group): segmental mobility (two), proximity to mental nerve or roots (two), radiologically unsatisfactory reduction (one) and unsatisfactory fixation (four) vs one (standard); only fixation differed…2 studiesGRADE not reported