Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

37 questions · 37 findings · 3 reviews · Implants and prosthodontics

No studies found 0 · 0%GRADE not reported 35 · 94.6%Very low 0 · 0%Low 1 · 2.7%Moderate 1 · 2.7%High 0 · 0%

IMZ TPS titanium cylinders vs ITI TPS hollow titanium screws

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

IMZ TPS titanium cylinders showed no clear difference in implant failure compared with ITI TPS hollow titanium screws; GRADE not reported.

1 finding from 1 review

Branemark Mark II turned titanium screws vs ITI TPS hollow titanium screws

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

Branemark Mark II turned titanium screws showed no clear difference in implant failure compared with ITI TPS hollow titanium screws; GRADE not reported.

1 finding from 1 review

IMZ TPS titanium cylinders vs ITI TPS solid titanium screws

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

IMZ TPS titanium cylinders showed no clear difference in implant failure compared with ITI TPS solid titanium screws; GRADE not reported.

1 finding from 1 review

Branemark Mark II turned titanium screws vs ITI TPS solid titanium screws

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

Branemark Mark II turned titanium screws showed no clear difference in implant failure compared with ITI TPS solid titanium screws; GRADE not reported.

1 finding from 1 review

Branemark turned titanium screws vs IMZ TPS titanium cylinders

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

Branemark turned titanium screws showed no clear difference in implant failure compared with IMZ TPS titanium cylinders; GRADE not reported.

1 finding from 1 review

NobelReplace Select Tapered implants vs NobelReplace implants

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

NobelReplace Select Tapered implants showed no clear difference in implant failure compared with nobelReplace Groovy implants; GRADE not reported.

1 finding from 1 review

ITI SLA standard (regular neck) implants vs ITI SLActive implants

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

ITI SLA standard (regular neck) implants showed no clear difference in implant failure compared with ITI SLActive implants; GRADE not reported.

1 finding from 1 review

Southern regular implants vs Southern wide implants

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

Southern regular implants showed no clear difference in implant failure compared with southern wide implants; GRADE not reported.

1 finding from 1 review

Astra TiO2-blasted titanium screws vs Branemark turned titanium screws

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

Astra TiO2-blasted titanium screws showed no clear difference in implant failure compared with branemark turned titanium screws; GRADE not reported.

1 finding from 1 review

NobelActive external connection implants vs NobelReplace implants

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

NobelActive external connection implants showed no clear difference in implant failure compared with nobelReplace implants; GRADE not reported.

1 finding from 1 review

Branemark Mark IV TiUnite titanium screws vs Southern regular titanium screws

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

Branemark Mark IV TiUnite titanium screws showed no clear difference in implant failure compared with southern regular titanium screws; GRADE not reported.

1 finding from 1 review

Maxillary sinus lift (augmentation) with long implants vs Short implants (5 to 8.5 mm) without sinus augmentation

Implant failure · Patients with missing teeth and an atrophic posterior maxilla, with residual bone height between 4 and 9 mm below the maxillary sinus

Maxillary sinus lift (augmentation) with long implants showed no clear difference in implant failure compared with short implants (5 to 8.5 mm) without sinus augmentation (moderate certainty).

1 finding from 1 review

Branemark Mark IV turned titanium implants vs Branemark Mark IV TiUnite oxidised implants

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

Branemark Mark IV turned titanium implants showed no clear difference in implant failure compared with branemark Mark IV TiUnite oxidised implants; GRADE not reported.

1 finding from 1 review

ITI SLActive titanium grade 4 implants vs ITI SLActive titanium-13zirconium (Roxolid) implants

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

ITI SLActive titanium grade 4 implants showed no clear difference in implant failure compared with ITI SLActive titanium-13zirconium (Roxolid) implants; GRADE not reported.

1 finding from 1 review

Steri-Oss acid-etched titanium screws vs Southern blasted/etched titanium screws

Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year

Steri-Oss acid-etched titanium screws showed no clear difference in implant failure compared with southern blasted/etched titanium screws; GRADE not reported.

1 finding from 1 review