Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Silica vs Fluorine showed no significant difference in 24 h bond strength (MD 1.441, 95% CI -5.099 to 7.980; Moderate certainty).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, HAp vs Calcium showed no significant difference in 24 h bond strength (MD -1.792, 95% CI -7.415 to 3.831; Low certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Etch-and-Rinse adhesive + biological ACAD protocol network, Flavonoids vs Fluorine showed no significant difference in 24 h bond strength (MD 4.241, 95% CI -2.652 to 11.135; Moderate certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · permanent human teeth with artificial caries-affected dentin
Calcium minus Control was -0.508 MPa (95% CI -8.207 to 7.191) at 24 h.
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Calcium Phosphate showed no significant difference in 24 h bond strength (MD -0.009, 95% CI -4.076 to 4.058; Low certainty).
3 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, HEMA vs Control showed no significant difference in 24 h bond strength (MD 1.899, 95% CI -3.210 to 7.009; Low certainty).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Calcium Phosphate vs Fluorine showed no significant difference in 24 h bond strength (MD 2.140, 95% CI -1.506 to 5.787; Moderate certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Calcium showed no significant difference in 24 h bond strength (MD 2.654, 95% CI -3.216 to 8.524; Moderate certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Silica vs Calcium showed no significant difference in 24 h bond strength (MD 1.964, 95% CI -5.802 to 9.730; Moderate certainty).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Fluorine showed no significant difference in 24 h bond strength (MD 2.131, 95% CI -2.213 to 6.475; Low certainty).
3 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Etch-and-Rinse adhesive + chemical ACAD protocol network, Calcium Phosphate vs Calcium showed no significant difference in 24 h bond strength (MD 0.596, 95% CI -7.289 to 8.482; Low certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
Only one in vitro study assessed a Self-Etch adhesive with the biological ACAD protocol; it was insufficient for network meta-analysis, so no pooled effect estimate is available (ungraded).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Control showed no significant difference in 24 h bond strength (MD 1.530, 95% CI -2.373 to 5.434; Moderate certainty).
3 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · permanent human teeth with artificial caries-affected dentin
Calcium phosphate minus Fluorine was -1.224 MPa (95% CI -5.931 to 3.482) at 24 h.
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Calcium vs Fluorine showed no significant difference in 24 h bond strength (MD -0.523, 95% CI -5.404 to 4.358; Low certainty).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Etch-and-Rinse adhesive + biological ACAD protocol network, Fluorine showed 4.197 MPa higher 24 h bond strength than Control (MD 4.197, 95% CI 1.080 to 7.314; Moderate certainty).
3 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Etch-and-Rinse adhesive + chemical ACAD protocol network, Peptide vs HAp showed no significant difference in 24 h bond strength (MD -0.288, 95% CI -7.988 to 7.411; Very Low certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, HAp vs HEMA showed no significant difference in 24 h bond strength (MD -4.815, 95% CI -10.709 to 1.079; Moderate certainty).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · permanent human teeth with artificial caries-affected dentin
Peptide minus Silica was -0.690 MPa (95% CI -7.941 to 6.560) at 24 h.
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Etch-and-Rinse adhesive + biological ACAD protocol network, Flavonoids showed 12.771 MPa lower 24 h bond strength than Calcium Phosphate (MD -12.771, 95% CI -20.538 to -5.003; Moderate certainty).
2 findings from 1 review