Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Calcium Phosphate vs Fluorine showed no significant difference in 24 h bond strength (MD 2.140, 95% CI -1.506 to 5.787; Moderate certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Etch-and-Rinse adhesive + chemical ACAD protocol network, Calcium Phosphate vs Calcium showed no significant difference in 24 h bond strength (MD 0.596, 95% CI -7.289 to 8.482; Low certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Calcium Phosphate vs Control showed no significant difference in 24 h bond strength (MD 1.539, 95% CI -1.738 to 4.817; Moderate certainty).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Calcium Phosphate showed no significant difference in 24 h bond strength (MD -0.009, 95% CI -4.076 to 4.058; Low certainty).
3 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Etch-and-Rinse adhesive + biological ACAD protocol network, Flavonoids showed 12.771 MPa lower 24 h bond strength than Calcium Phosphate (MD -12.771, 95% CI -20.538 to -5.003; Moderate certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, HEMA vs Calcium Phosphate showed no significant difference in 24 h bond strength (MD 0.360, 95% CI -5.589 to 6.309; Moderate certainty).
1 finding from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, HAp showed 4.455 MPa lower 24 h bond strength than Calcium Phosphate (MD -4.455, 95% CI -8.857 to -0.053; Moderate certainty).
2 findings from 1 review
Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)
In the Self-Etch adhesive + chemical ACAD protocol network, Silica vs Calcium Phosphate showed no significant difference in 24 h bond strength (MD -0.699, 95% CI -7.633 to 6.234; Moderate certainty).
1 finding from 1 review