Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

31 questions · 43 findings · 2 reviews

No studies found 14 · 32.6%GRADE not reported 0 · 0%Very low 16 · 37.2%Low 11 · 25.6%Moderate 2 · 4.7%High 0 · 0%

Intratympanic corticosteroids vs systemic corticosteroids

Change in hearing threshold determined by PTA Range 0 dB to 140 dB Negative values represent lowering and positive values represent raising of the hearing threshold. A lower hearing threshold represents hearing improvement. Â · sudden sensorineural hearing loss

Intratympanic corticosteroids showed no clear difference in change in hearing threshold determined by PTA Range 0 dB to 140 dB… compared with systemic corticosteroids (low certainty).

1 finding from 1 review

Intratympanic corticosteroids vs systemic corticosteroids

Final hearing threshold determined by PTA (a lower value represents better hearing) · sudden sensorineural hearing loss

Intratympanic corticosteroids showed no clear difference in final hearing threshold determined by PTA (a lower value represents… compared with systemic corticosteroids (low certainty).

1 finding from 1 review

Intratympanic corticosteroids vs placebo/no treatment

Improvement in vertigo frequency · Ménière’s disease

Intratympanic corticosteroids showed no clear difference in improvement in vertigo frequency compared with placebo/no treatment (low certainty).

2 findings from 1 review

Intratympanic corticosteroids vs placebo/no treatment

Change in vertigo frequency · Ménière’s disease
3 findings from 1 review

Intratympanic corticosteroids vs no treatment or versus placebo

Change in hearing threshold determined by PTA Range 0 dB to 140 dB Negative values represent lowering and positive values represent raising of the hearing threshold. A lower hearing threshold represents hearing improvement. Â · sudden sensorineural hearing loss

Intratympanic corticosteroids showed no clear difference in change in hearing threshold determined by PTA Range 0 dB to 140 dB… compared with no treatment or versus placebo (low certainty).

1 finding from 1 review

Intratympanic corticosteroids vs no treatment or versus placebo

Final hearing threshold determined by PTA (a lower value represents better hearing) · sudden sensorineural hearing loss

Intratympanic corticosteroids showed no clear difference in final hearing threshold determined by PTA (a lower value represents… compared with no treatment or versus placebo (low certainty).

1 finding from 1 review