Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

2 questions · 2 findings · 1 reviews · Oral and maxillofacial surgery

No studies found 0 · 0%GRADE not reported 2 · 100%Very low 0 · 0%Low 0 · 0%Moderate 0 · 0%High 0 · 0%

2 mm titanium plates vs 2.5 mm bioresorbable plates

Post-operative neurosensory disturbance (mental nerve paraesthesia) · Adults (16 to 68 years) with mandibular fractures excluding condylar involvement

2 mm titanium plates led to higher post-operative neurosensory disturbance (mental nerve paraesthesia) compared with 2.5 mm bioresorbable plates; GRADE not reported.

1 finding from 1 review

Locking plate vs 2 mm non-locking titanium plates

Post-operative adverse events and complications (paraesthesia, swelling, segmental mobility) · Adults (16 to 68 years) with mandibular fractures excluding condylar involvement
1 finding from 1 review
  • Agarwal 2011: paraesthesia in one participant in the non-locking plate group (resolved by 3 months), none in the locking group; infection rates similar at 6 weeks and 3 months; post-operative swelling in 20% of both…
    1 study
    GRADE not reported