Direct trocar entry vs Veress needle entry
Direct trocar entry probably leads to lower failed entry compared with veress needle entry (moderate certainty).
- Peto OR 0.24 [0.17, 0.34]8 studies · 3185 participantsModerate
Direct trocar entry probably leads to lower failed entry compared with veress needle entry (moderate certainty).
The review found no eligible studies for this question.
It is very uncertain whether direct vision entry changes vascular injury (major vessels and abdominal wall vessels) compared with veress needle entry (very low certainty).
It is very uncertain whether direct vision entry changes visceral injury (bladder or bowel) compared with veress needle entry (very low certainty).
The review found no eligible studies for this question.
The review found no eligible studies for this question.
The review found no eligible studies for this question.
The review found no eligible studies for this question.
It is very uncertain whether open‐entry changes vascular injury (major vessels and abdominal wall vessels) compared with closed‐entry technique (very low certainty).
It is very uncertain whether direct vision entry changes visceral injury (bladder or bowel) compared with open‐entry technique (very low certainty).
The review found no eligible studies for this question.
It is very uncertain whether direct vision entry changes solid organ injury compared with open‐entry technique (very low certainty).
It is very uncertain whether direct vision entry changes failed entry compared with open‐entry technique (very low certainty).
The review found no eligible studies for this question.
It is very uncertain whether radially expanding (STEP) trocars for primary port entry changes vascular injury (major vessels and abdominal wall vessels) compared with standard (non‐expanding) trocars (very low certainty).
It is very uncertain whether radially expanding (STEP) trocars for primary port entry changes visceral injury (bladder or bowel) compared with standard (non‐expanding) trocars (very low certainty).
The review found no eligible studies for this question.
It is very uncertain whether radially expanding (STEP) trocars for primary port entry changes solid organ injury compared with standard (non‐expanding) trocars (very low certainty).
It is very uncertain whether open‐entry changes visceral injury (bladder or bowel) compared with closed‐entry technique (very low certainty).